Schneider Electric G12F3F50 — Miniature Circuit Breakers (MCB)

Schneider Electric G12F3F50 GoPact MCCB 125, 50A, 30kA, 3P

MPNG12F3F50
Active

Schneider Electric GoPact MCCB 125, thermal-magnetic, 3P, 50 A, 30 kA at 415 V AC, IP20, grey (RAL 7035).

$80.13Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

G12F3F50 — Identification
ParameterValue
Product nameGoPact MCCB 125
Product range (series)GoPact MCCB
Product/component typeCircuit breaker
Device applicationDistribution
G12F3F50 — Ratings
ParameterValue
Rated current (In)50 A at 40 °C
Poles configuration3P
Rated operational voltage (Ue)415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated insulation voltage (Ui)440 V AC conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Utilisation categoryCategory A
Overvoltage categoryIII
G12F3F50 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)8000 cycles at 415 V In
Mechanical durability (cycles)30000 cycles
G12F3F50 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
G12F3F50 — Environmental
ParameterValue
Operating ambient temperature-20...55 °C
Storage ambient temperature-35...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
G12F3F50 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H
G12F3F50 — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity30 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity15 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
G12F3F50 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range1 x In
Trip unit protection functionsLI

Product details

The G12F3F50 is a Schneider Electric GoPact MCCB 125 — a fixed-mount, 3-pole thermal-magnetic moulded-case circuit breaker rated 50 A at 40 °C with an F-class breaking capacity of 30 kA at 380/415 V AC. It is built to EN/IEC 60947-2 (and Annex H for selective coordination), carries an insulation voltage of 440 V AC, and is rated for operational voltage of 415 V AC at 50/60 Hz. The TM-D trip unit gives LI protection — thermal for overload (L), magnetic for short-circuit (I). That is the standard combo for distribution feeders: no ground-fault or electronic adjustment, just reliable bimetal and solenoid action.

Thermal environment and mounting reality

Ambient operating range is -20 to 55 °C, storage from -35 to 85 °C. Power dissipation is 18.7 W per pole. Connection pitch is 25 mm, terminals are screw type, and both line and load connections are front-accessed.

Mechanical endurance is 30,000 cycles; electrical endurance is 8,000 cycles at rated current and 415 V. That electrical figure tells you this breaker is meant for infrequent switching — it is a distribution protector, not a motor-starting contactor. If your application cycles the breaker weekly, 8,000 cycles is decades of service. If it cycles daily, you will wear out the contacts sooner and should consider a contactor in series. Utilisation category A means it is not specifically rated for high-frequency switching of motors or capacitive loads — standard distribution duty. Altitude rating: full performance up to 2000 m, derated above that up to 5000 m. If your site is above 2000 m, factor in the reduced dielectric strength and cooling.

Frequently asked questions

What is the breaking capacity of the G12F3F50?

The G12F3F50 has an F-class breaking capacity of 30 kA at 380/415 V AC, which is the standard F performance level for this GoPact MCCB range.

What standards does the G12F3F50 comply with?

It complies with EN/IEC 60947-1, EN/IEC 60947-2, and EN/IEC 60947-2 Annex H for selective coordination.

What is the trip unit type and protection functions?

It uses a TM-D thermal-magnetic trip unit with LI protection: thermal for overload (L) and magnetic for short-circuit (I).