Skip to main content
Schneider Electric ILT2V423MC0A

Schneider Electric ILT2V423MC0A

MPNILT2V423MC0A
Obsolete

integrated drive ILT with stepper motor - 24..48V DC - Pulse/Direction - 0.39N.m

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

ILT2V423MC0A key specifications
ParameterValue
Motor type2-phase stepper motor
Network typeDC
Winding typeMedium speed of rotation and medium torque
Feedback typeWithout
Gear box typeWithout
Protection typeShort circuit of the output voltage Overload of output voltage
Range of productLexium integrated drive
Input (output type)3 inputs (Step Clock, Direction, Enable)
Product or component typeMotion integrated drive
Supply voltage limits12...48 V
Supply voltage24...48 V
Voltage state 1 guaranteed>= 2.2 V

All specifications

ILT2V423MC0A additional specifications
ParameterValue
Current consumption1.3 A maximum continuous
IP degree of protectionIP41 shaft bushing: conforming to EN/IEC 60034-5 IP54 total except shaft bushing: conforming to EN/IEC 60034-5
Communication interfacePulse/Direction 5 -24 V
Mounting supportFlange
Electrical connectionIndustrial connector
Relative humidity15...85 % without condensation
Operating altitude<= 1000 m without derating
StandardsEN 61000-3-2 : 2006 IEC 61000-4-5 EN 61000-3-3:1995, A1:2001, A2:2005 IEC 61000-4-11 IEC 61000-4-3 EN 55011:2007, A2:2007 for Group 1, Class A EMC immunity IEC 61000-4-2 IEC 61000-4-4 IEC 61000-4-6
Length3.6 in (92.2 mm)
MarkingCE
Holding brakeWithout
Nominal speed400 rpm 24 V 600 rpm 48 V
Rotor inertia0.082 kg.cm²
Accuracy error+/- 0.3 arc/min
Holding torque3.45 lbf.in (0.39 N.m)
Device short nameILT
Motor flange size1.7 in (42 mm)
Peak stall torque3.45 lbf.in (0.39 N.m)
Service life in hours20000 h
Continuous stall torque3.45 lbf.in (0.39 N.m)
Speed feedback resolution1000 steps 10000 steps 12800 steps 1600 steps 200 steps 2000 steps 20000 steps 25000 steps 25600 steps 3200 steps 400 steps 40000 steps 5000 steps 50000 steps 51200 steps 6400 steps 800 steps
Ambient air temperature for storage-13...158 °F (-25...70 °C)
Ambient air temperature for operation122...149 °F (50...65 °C) (with power derating of 2 % per °C) 32...122 °F (0...50 °C) (without derating)
Permissible ambient air temperature around the device212 °F (100 °C)
MPN
ILT2V423MC0A