Skip to main content
Schneider Electric LP5K0601NW3 — Contactors

Schneider Electric TeSys K LP5K0601NW3 Reversing Contactor,

MPNLP5K0601NW3
Active

Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 6 A, 1 NC, 60 V DC coil, preassembled with reversing power busbar.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LP5K0601NW3 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LP5K0601NW3 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-4
LP5K0601NW3 — Contacts & Poles
ParameterValue
Pole configuration3P
LP5K0601NW3 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP5K0601NW3 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The LP5K0601NW3 is a Schneider Electric TeSys K reversing contactor, 3-pole, rated for AC-3 duty at ≤440 V and 6 A, with a 60 V DC coil and one NC auxiliary contact.

AC-3 and AC-4 utilisation categories mean this contactor is designed for starting and plugging/reversing of squirrel-cage motors. The 6 A at ≤440 V AC-3 figure governs motor selection. IP20 finger-safe terminals mount inside an IP54 or higher enclosure.

This reversing contactor is the core component in a motor-reversing circuit for a three-phase induction motor — think conveyor direction change, actuator extend/retract, or pump rotation reversal. It lives inside a control panel, typically on a DIN rail, and is switched by a PLC or relay output through the 60 V DC coil. The preassembled busbar saves panel wiring time and eliminates the risk of a mis-wired interlock.

Mechanical and environmental robustness

Rated for 15 Gn shock when closed (Z-axis) and 4 Gn vibration from 5–300 Hz when closed — this contactor holds in under moderate machine vibration, which matters for reversing duty where the contactor stays closed during the run cycle. Storage temperature range -50 to 80 °C, operating -25 to 50 °C. Altitude derating starts above 2000 m. Flame retardance meets UL 94 V1 and NF F 16-101/102, which is relevant for rail and industrial panel fire-safety requirements.

MPN