Skip to main content
Schneider Electric LZ7H2X4FU

Schneider Electric LZ7H2X4FU

MPNLZ7H2X4FU
Obsolete

Ultra compact starter, TeSys Hybrid, Safe Torque Off, 3P, 500VAC, 0.75kW at 400V, 110 to 230VAC

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LZ7H2X4FU key specifications
ParameterValue
Motor starter typeDirect on line
Product or component typeUltra-compact starter
Coil voltage110...230 V AC 50/60 Hz
Voltage500 V AC 50/60 Hz
Control circuit voltage limits85...253 V AC
[Ue] rated operational voltage500 V AC
[Uimp] rated impulse withstand voltage4 kV
Current consumption<= 4 mA 110...230 V AC
[Ie] rated operational current2.4 A 500 V AC-51 2.4 A 500 V AC-53A 2.4 A 500 V AC-51 mounting side by side 2.4 A 500 V AC-53A mounting side by side
Motor power0.37 kW 220 V AC 0.65 0.37 kW 230 V AC 0.65 0.75 kW 380 V AC 0.65 0.75 kW 400 V AC 0.65 0.75 kW 415 V AC 0.65 0.75 kW 440 V AC 0.65 1.1 kW 500 V AC 0.65
Maximum horse power rating0.5 hp 200 V AC 0.5 hp 230 V AC 1 hp 460 V AC
Poles description3P

All specifications

LZ7H2X4FU additional specifications
ParameterValue
IP degree of protectionIP20
Mounting modeBy clips
Mounting supportDIN rail
Connections - terminalsscrew clamp terminals 1 0.0003...0.004 in² (0.2...2.5 mm²) rigid screw clamp terminals 1 0.0004...0.004 in² (0.25...2.5 mm²) flexible - with cable end screw clamp terminals 1 0.0003...0.004 in² (0.2...2.5 mm²) flexible - without cable end
Pollution degree2
Depth4.5 in (114.5 mm)
Width0.9 in (22.5 mm)
Height3.9 in (99 mm)
Electrical durability30 Mcycles
StandardsIEC 60947-4-2 UL 60947-4-1
CertificationsCE CULus ATEX as associated device for motor protection in zones 1 and 21
RangeTeSys
ResetManual Electrical reset
CategoryUS10I1222349
Safety levelSIL 3 IEC 61508-1 stop function PL = e ISO 13849-1 stop function SIL 2 IEC 61508-1 motor protection
Device short nameLZ7H
Tightening torque4.4...5.3 lbf.in (0.5...0.6 N.m) flat Ø 2.5 mm screwdriver 0.1 in (3 mm)
Protective treatmentTC
Maximum operating rate120 cyc/mn AC-51 50 % 6 cyc/mn AC-53A 50 %
Thermal overload classClass 10A IEC 60947-4-2
Safety reliability dataSFF = 99 % stop function SFF = 99 % motor protection MTTFd = 289 years stop function MTTFd = 273 years motor protection PFHd = 6.27E-9 1/h stop function
Auxiliary contact composition1 C/O fault signalling
Ambient air temperature for storage-40...176 °F (-40...80 °C)
Thermal protection adjustment range0.18...2.4 A
Ambient air temperature for operation-13...149 °F (-25...65 °C) without derating 149...158 °F (65...70 °C) with derating
MPN
LZ7H2X4FU