Schneider Electric RE88896203
MPNRE88896203
Active
miniature timing relay - 0..100 h - 24 V AC, 50/60 Hz - 4 C/O
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
Specifications
| Parameter | Value |
|---|---|
| Time delay type | A |
| Range of product | Zelio Time |
| Discrete output type | Relay |
| Product or component type | Miniature timing relay |
| Contacts type and composition | 4 C/O timed or instantaneous contact, AgNi |
| Voltage drift | +/- 0.2 %/V |
| Voltage range | 0.85...1.15 Un |
| Surge withstand | 1 kV differential mode EN/IEC 61000-4-5 level 3 2 kV common mode EN/IEC 61000-4-5 level 3 |
| Immunity to voltage dips | >= 95 % / 5 s IEC 61000-4-11 30 % / 10 ms IEC 61000-4-11 60 % / 0.1...1 s IEC 61000-4-11 |
| Maximum switching voltage | 250 V AC |
| Supply voltage | 24 V AC 50/60 Hz |
| Nominal output current | 0.1...3 A |
All specifications
| Parameter | Value |
|---|---|
| Power consumption in | 1250 VA |
| IP degree of protection | IP50 IEC 60529 casing) |
| Electrical connection | 14 plug-in sub-base |
| Relative humidity | 0...95 % without condensation IEC 60068-2-3 |
| Vibration resistance | 0.35 mm (f= 10...55 Hz) conforming to IEC 60068-2-6 |
| Housing material | Polycarbonate |
| Electrical durability | 100000 cycles 250 V AC resistive |
| Mechanical durability | 10000000 cycles |
| Standards | EN/IEC 60601-1 EN/IEC 60601-1-2 EN/IEC 61812-1 EN 61000-6-2 EN 50081-2 |
| Category | 22370-RE, RM MISC TIMERS & COUNTERS |
| Reset time | 250 ms after time delay period 50 ms during time delay period |
| Component name | RE88896 |
| On-load factor | 100 % |
| Repeat accuracy | +/- 0.5 % |
| Local signalling | 1 LED (green) for power ON 1 LED (yellow) for output status |
| Time delay range | 0.1...1 s 0.1...1 min 0.1...1 h 1...10 h 10...100 h 1...10 s 1...10 min |
| Temperature drift | +/- 0.05 %/°C |
| Immunity to microbreaks | 5 ms |
| Product front plate size | 21 x 27 mm |
| Electromagnetic compatibility | Class 2 EN 61812-1 |
| Resistance to fast transients | 1 kV IEC 61000-4-4 level 3 coupled) 2 kV IEC 61000-4-4 level 3 direct) |
| Disturbance radiated (conducted) | Class B EN 55022 (EN 55011 group 1) |
| Setting accuracy of time delay | 0 %/+ 10 % of full scale 77 °F (25 °C) EN/IEC 61812 |
| Immunity to radioelectric fields | 10 V 0.15...80 MHz)IEC 61000-4-6 level 3 |
| Ambient air temperature for storage | -40...158 °F (-40...70 °C) |
| Resistance to electromagnetic fields | 9.1 V/m (10 V/m) 26...1000 MHz ENV 50140/204 level 3 |
| Ambient air temperature for operation | -4...140 °F (-20...60 °C) |
| Resistance to electrostatic discharge | 6 kV on contact EN/IEC 61000-4-2 level 3 8 kV in air EN/IEC 61000-4-2 level 3 |
MPN
RE88896203