Schneider Electric REL15002
MPNREL15002
Active
Easergy P1F 24-250V 3CT 1Io: 0.01-2IN 0DI-4DO RS485
$1,041.40Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
Specifications
| Parameter | Value |
|---|---|
| Display type | Graphic display terminal |
| Range of product | PowerLogic |
| Product or component type | Protection relay |
| Switchgear diagnosis type | Trip circuit supervision ANSI code: TCS |
| Type of temperature module connection | 1 twisted shielded pair |
| Power supply | 24...240 V AC 24...250 V DC |
| Maximum power consumption in | 13.5 W AC 4 W DC |
| IP degree of protection | IP54 conforming to IEC 60529 |
| Communication ports | 1 RS485 on rear |
| Communication protocols | CEI 60870-5-103 Modbus RTU |
| Communication compatibility | IEC 60870-5-103 Modbus RTU |
| Mounting mode | Flush-mounted |
All specifications
| Parameter | Value |
|---|---|
| Device mounting | Flush |
| Mounting support | Fixing kit |
| Device connection | Serial port 1 shielded twisted pair |
| Connections - terminals | Snap-on fixed |
| Relative humidity | 0...93 % at 40 °C, 21 days 0...93 % at 60 °C, 10 days 93 % at 25...55 °C, 6 cycles, 12 + 12 hours |
| Depth | Embedded : 108 mm Total : 119 mm |
| Width | Embedded: 101.5 mm Total: 116.5 mm |
| Height | Embedded: 101.5 mm Total: 116.5 mm |
| Standards | EN 60255-26:2009 EN 60255-1:2010 EN 60255-27:2005 |
| Directives | 2006/95/EC - low voltage directive 2004/108/EC - electromagnetic compatibility |
| Cybersecurity | Password protection |
| Number of key | 9 |
| Local signalling | 6 x LED red/orange programmable 1 x LED red relay trip indicator 1 x LED green watchdog |
| Logs and records | Trip context information |
| Measuring inputs | : 1/5 A CT phase current 0 |
| Control functions | I/O push-button |
| Product reference | P1 |
| Relay application | Feeder |
| Arc flash protection | No |
| Monitoring functions | Trip circuit supervision 74 Relay self-monitoring |
| Protection functions | Breaker failure 50BF Phase overcurrent 50/51 Earth fault overcurrent 50N/51N Lockout relay 86 Cold load pick-up |
| Measurement functions | Current 3-phase Current RMS Current peak Frequency |
| Mechanical robustness | Seismic tests: 2 Gn horizontal, 1 Gn vertical conforming to EN 60255-21-3 Shocks (level: class 1) : 5 Gn for 11 ms conforming to EN 60255-21-2 Shocks withstand (level: class 1) : 10 Gn for 16 ms conforming to EN 60255-21-2 Bumps (level: class 1) : 15 Gn for 11 ms conforming to EN 60255-21-2 Vibrations (level: class 1) : 1 Gn, 10...150 Hz, 1 cycle conforming to EN 60255-21-1 |
| Electromagnetic compatibility | Electromagnetic immunity level 3 conforming to EN 61000-4-2/3/4/5/6/8 |
| Number of digital inputs | 0 |
| Number of digital outputs | 4 DO 1 watchdog |
| Ambient air temperature for storage | -30...70 °C |
| Ambient air temperature for operation | -25...60 °C -30...70 °C ( 16 h ) |
MPN
REL15002