Mitsubishi Electric FR-E840-0120-4-60 — AC Drive (VFD) 480V

Inverter Mitsubishi FR-E840-0120-4-60, kelas 400 V

MPNFR-E840-0120-4-60

Mitsubishi, inverter seri FR-E800, input 3 fase kelas 400 V, rating ND, slot 0120, PCB berlapis conformal tanpa konduktor berlapis, kode pesanan FR-E840-0120-4-60.

$764.00Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

FR-E840-0120-4-60 — Specifications
ParameterValue
4400 V class
-4Monitoring/protocol specifications : Voltage (terminal AM)Rated frequency (initial setting) : 50 HzInput signal (initial status) : Source logicSafety stop signal : Source logic (fixed)
-60Circuit board coating : With coatingPlated conductor : Without plated conductors
0120Inverter ND rated current (A)
NoneThree-phase input
Weight2.4 Kg
Product typeInverter FR-E800
Plated conductorWithout plated conductors
Safety stop signalSource logic (fixed)
Circuit board coatingWith coating
Input signal (initial status)Source logic
Rated frequency (initial setting)50 Hz
Monitoring (protocol specifications)Voltage (terminal AM)

Product details

Apa arti strip sufiks bagi meja kerja wiring

FR-E840-0120-4-60: Bagi integrator kontrol, itu menentukan ekspektasi di meja kerja — input safe-stop mengharapkan sinyal sourcing dan tidak dapat dikonfigurasi ulang, dan input digital default ke logika source sehingga sensor sinking perlu flip parameter sebelum commissioning.

Postur sourcing untuk lini BOM

Dengan lifecycle ditandai current dan tanpa kode penerus resmi dalam catatan, langkah pengadaan adalah memasukkan FR-E840-0120-4-60 ke dalam BOM sebagai quoted-to-order dan membiarkan RFQ menentukan lead time serta konfirmasi kanal resmi.

Frequently asked questions

Is the FR-E840-0095-4-60 a direct second source for the FR-E840-0120-4-60?

No — it is the next-smaller ND-rated slot in the same 400 V class, conformal-coated -60 build and same AM/50 Hz/source-logic monitoring bundle, but the output rating and mounting footprint differ, so a panel designed around the 0095 needs a re-check rather than a straight swap.

What does the '4' in FR-E840-0120-4-60 mean?

It marks the 400 V input class, paired with three-phase input on this build.

What does the '-4' suffix bundle define?

It sets the monitoring defaults: terminal AM as the voltage analog output, initial rated frequency 50 Hz, input signal source logic, and safety stop signal source logic (fixed).

MPN
FR-E840-0120-4-60