Skip to main content
Schneider Electric A9R41492

Schneider Electric A9R41492

MPNA9R41492
Active

A9R41492 by SCHNEIDER ELECTRIC

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9R41492 key specifications
ParameterValue
Control typeToggle
Network typeAC
Product or component typeResidual current circuit breaker (RCCB)
Voltage400 V AC 50 Hz conforming to IEC/EN 61008-1 400 V AC 50 Hz conforming to IEC/EN 61008-2-1
[Ue] rated operational voltage400 V AC 50 Hz conforming to IEC/EN 61008-1 400 V AC 50 Hz conforming to IEC/EN 61008-2-1
[Uimp] rated impulse withstand voltage4 kV conforming to IEC/EN 61008-1 4 kV conforming to IEC/EN 61008-2-1
Current125 A
Residual current tripping technologyVoltage independent
Rated conditional short-circuit currentInc 10 kA 125 A
Network frequency50 Hz
Poles description4P
IP degree of protectionIP20 conforming to IEC/EN 60529 IP20 conforming to IEC/EN 62423 IP40 (modular enclosure) conforming to IEC/EN 60529 IP40 (modular enclosure) conforming to IEC/EN 62423

All specifications

A9R41492 additional specifications
ParameterValue
Mounting modeFixed
Mounting support35 mm symmetrical DIN rail
Connection pitch18 mm between phases
Wire stripping length11 mm
Connections - terminalsTunnel type terminals2 cable(s) 1.5...16 mm² flexible Tunnel type terminals2 cable(s) 1.5...16 mm² rigid Tunnel type terminals1 cable(s) 1.5...50 mm² rigid Tunnel type terminals1 cable(s) 1.5...35 mm² flexible Tunnel type terminals1 cable(s) 1.5...35 mm² flexible with ferrule Tunnel type terminals2 cable(s) 1.5...16 mm² flexible with ferrule
Pollution degree3
Depth76 mm
Width72 mm
ColorGrey
Height86 mm
Electrical durability2000 cycles
Mechanical durability5000 cycles
StandardsIEC/EN 61008-1 IEC/EN 61008-2-1 IEC/EN 62423
RangeActi9
9 mm pitches8
Quality labelsVDE
Local signallingRed/green indicator Trip indicator
Neutral positionLeft
Device short nameRCCB-ID
Tightening torque3 N.m
Provision for padlockingPadlockable
Device location in systemOutgoer
Earth-leakage sensitivity30 mA
Contact position indicatorYes
Electromagnetic compatibility8/20 µs impulse withstand, 3 kA conforming to IEC/EN 61008-1 8/20 µs impulse withstand, 3 kA conforming to IEC/EN 61008-2-1
Earth-leakage protection classType B
Rated breaking and making capacityIm = 1250 A 400 V conforming to IEC/EN 61008-1 Im = 1250 A 230 V conforming to IEC/EN 61008-2-1
Ambient air temperature for storage-40...60 °C
Earth-leakage protection time delayInstantaneous
Ambient air temperature for operation-25...40 °C
MPN
A9R41492