Skip to main content
Schneider Electric A9R60240 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9R60240 Acti9 iID K RCCB, 40 A, 30 mA, 2

MPNA9R60240
Active

Schneider Electric Acti9 iID K RCCB, 40 A, 30 mA, 2P, Type AC, 220-240 V AC, clip-on DIN rail, IP20/IP40.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9R60240 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R60240 — Electrical Ratings
ParameterValue
Rated current (In)40 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)440 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 2000 cycles
Mechanical durability (operating cycles)5000 cycles
A9R60240 — Identification
ParameterValue
Product nameActi9 iID K
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID K
A9R60240 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals top or bottom 1...35 mm² rigid Tunnel type terminals top or bottom 1...25 mm² flexible Tunnel type terminals top or bottom 1...25 mm² flexible with ferrule
Wire stripping length16 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height85 mm
Depth69 mm
A9R60240 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree2
A9R60240 — Approvals
ParameterValue
StandardsEN/IEC 61008-1 EN/IEC 61008-2-1

Product details

The Schneider Electric A9R60240 is a 2-pole residual current circuit breaker (RCCB) from the Acti9 iID K series, rated at 40 A with 30 mA earth-leakage sensitivity.

The 40 A rated current (In) suits branch circuits feeding groups of sockets, lighting, or small appliances — not a main switch or heavy motor load. Breaking capacity is 500 A (Idm/Im), adequate for fault clearing in a domestic or light commercial distribution board where prospective short-circuit current is typically below that level.

Carries VDE quality label. The 8/20 µs impulse withstand of 200 A per EN/IEC 61008-1 means it survives common surge events without nuisance tripping. Pollution degree 2 (non-conductive pollution only) is typical for clean indoor environments.

Lifecycle stage is marked as current — this is an active, in-production part from Schneider Electric's standard Acti9 range. No end-of-life or last-time-buy notice applies.

Frequently asked questions

Where can I buy the A9R60240 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at the time of quote — submit an RFQ for a firm price and lead time.

What is the closest alternative to A9R60240 in the Acti9 family?

Within the Acti9 iID range, the closest alternative would be a different sensitivity or current rating — for example, a 30 mA / 25 A or 30 mA / 63 A variant. Pin-compatible in the same 2P 4-module footprint, but the trip current differs. No direct pin-compatible substitute with identical ratings exists outside the iID K series.

What compliance documentation does Schneider provide for A9R60240?

The part is certified to EN/IEC 61008-1 and EN/IEC 61008-2-1, and carries a VDE quality label. Standard Schneider documentation includes a declaration of conformity covering these standards.

MPN
A9R60240