Skip to main content
Schneider Electric A9Z82440 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9Z82440 Acti9 iID RCCB, 40A 100mA 4P Typ

MPNA9Z82440
Active

Schneider Electric Acti9 iID RCCB, A9Z82440, 4P, 40 A rated, 100 mA sensitivity, Type A, 380-415 V AC, DIN-rail clip-on.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9Z82440 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)100 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9Z82440 — Electrical Ratings
ParameterValue
Rated current (In)40 A
Rated operational voltage (Ue)380...415 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Electrical durabilityAC-1: 15000 cycles
Mechanical durability (operating cycles)20000 cycles
A9Z82440 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9Z82440 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules8
Terminal connectionsDouble terminal front 1...35 mm² rigid Double terminal front 1...25 mm² flexible Double terminal front 1...25 mm² flexible with ferrule Double terminal back 1...25 mm² rigid Double terminal back 1...16 mm² flexible Double terminal back 1...16 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width72 mm
Height91 mm
Depth73 mm
A9Z82440 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9Z82440 — Approvals
ParameterValue
StandardsEN/IEC 61008-1 EN/IEC 61008-2-1

Product details

The Schneider Electric A9Z82440 is a 4-pole residual current circuit breaker (RCCB) from the Acti9 iID range, rated 40 A with 100 mA earth-leakage sensitivity. That covers most modern loads with rectifiers or switching supplies, not just plain resistive heaters.

Clip-on mounting on DIN rail, 8 x 9 mm pitches wide (72 mm). Neutral on the left. Strip 14 mm for top or bottom connection.

Electrical performance and coordination

Rated conditional short-circuit current of 10 kA, with a making/breaking capacity Idm of 1500 A. Impulse withstand voltage 6 kV, pollution degree 3. The RCCB is voltage-independent — it trips on residual current alone, no auxiliary supply needed. Instantaneous time delay, so it responds immediately to earth faults. Electrical durability 15,000 cycles (AC-1), mechanical 20,000 cycles.

Frequently asked questions

Who supplies A9Z82440 and how is it quoted for volume purchases?

We supply the A9Z82440 through our independent distribution channel. It is quoted to order against an RFQ; availability and current pricing are confirmed at the time of quote.

What is the closest alternative to A9Z82440 in the Acti9 family?

Within the Acti9 iID range, the closest alternative would be a different sensitivity or current rating — for example, a 30 mA version for personnel protection instead of the 100 mA equipment-protection sensitivity of this unit. The mechanical footprint and wiring are identical.

What compliance documentation does Schneider provide for A9Z82440?

The A9Z82440 is designed to EN/IEC 61008-1 and EN/IEC 61008-2-1 standards. It carries IP20/IP40 ratings per IEC 60529. For specific RoHS, REACH, or UL documentation, the manufacturer's compliance declarations are available on request.

MPN