Schneider Electric C10S2TM080 — Miniature Circuit Breakers (MCB)

Schneider Electric C10S2TM080 ComPacT NSX 80A 2P MCCB, 70kA

MPNC10S2TM080
Active

Schneider Electric ComPacT NSX, NSX100S, 80 A, 2-pole, thermal-magnetic MCCB, 70 kA Icu at 415 V AC, toggle control.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

C10S2TM080 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C10S2TM080 — Ratings
ParameterValue
Rated current (In)80 A at 40 °C
Poles configuration2P
Breaking capacity100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 250 V DC 1 pole conforming to IEC 60947-2 100 kA Icu at 500 V DC 2 poles in series conforming to IEC 60947-2 100 kA Icu at 500 V DC 2P conforming to IEC 60947-2
Rated service breaking capacity (Ics)100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 250 V DC conforming to IEC 60947-2 100 kA at 500 V DC conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz 500 V DC
Rated insulation voltage (Ui)750 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C10S2TM080 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)20000 cycles at 277 V In/2 10000 cycles at 277 V In
Mechanical durability (cycles)20000 cycles
C10S2TM080 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C10S2TM080 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C10S2TM080 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C10S2TM080 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range1 x In
Trip unit protection functionsLI

Product details

80 A MCCB with a breaking-capacity ladder that covers most distribution panels

The Schneider Electric C10S2TM080 is a ComPacT NSX100S 2-pole MCCB rated 80 A at 40 °C with a TM-D thermal-magnetic trip unit. The TM-D provides L (overload, thermal) and I (short-circuit, magnetic) protection — the standard dual-slop curve for distribution and light motor feeder duty. The 70 mm wide, 161 mm high fixed-mount body (86 mm depth) fits backplate-mount panels with a 35 mm connection pitch. The S breaking capacity code means 70 kA Icu at 415 V AC, 100 kA at 240 V AC, and 35 kA at 525 V AC — enough headroom for most industrial distribution boards without cascading upstream.

Above 40 °C the trip unit derates — the thermal element responds to ambient heat, so a panel running at 50 °C needs a higher-rated frame or forced ventilation. The 100 kA at 240 V AC covers high-fault residential or light commercial service entrances; the 35 kA at 525 V AC suits 480 V industrial systems. The 2-pole configuration (2P) protects two phases or one phase plus neutral in a single-phase or split-phase distribution. The TM-D trip unit has a fixed magnetic pickup — no interchangeable rating plugs — so the 80 A setting is permanent.

Deployment context

The IK07 impact rating (per IEC 62262) handles accidental tool drops during maintenance. Pollution degree 3 (IEC 60664-1) means it tolerates conductive dust in industrial environments without conformal coating.

Frequently asked questions

What is the breaking capacity of C10S2TM080 at 415 V?

70 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. The S breaking capacity code designates this 70 kA level at 415 V.

What is the closest alternative to C10S2TM080 in the ComPacT NSX family?

Within the same NSX100S frame, the closest alternative would be a different trip unit rating (e.g., 63 A or 100 A TM-D) or a different breaking capacity code (H or L). The C10S2TM080 is the 80 A, 2-pole, S-breaking-capacity variant; a 3-pole version or one with an electronic Micrologic trip unit would differ in form factor and protection curve. No direct pin-compatible substitute exists — the trip rating is fixed to the breaker.

Where can I buy C10S2TM080 and how is it quoted?

The C10S2TM080 is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

MPN
C10S2TM080