Schneider Electric ComPacT NSX, NSX100HB2, 3P, 100 A at 40 °C, thermal-magnetic TM-D trip unit, 100 kA Icu at 690 V AC, IP40, backplate mount.

$496.57Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C10W3TM100 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C10W3TM100 — Ratings
ParameterValue
Rated current (In)100 A at 40 °C
Poles configuration3P
Breaking capacity100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C10W3TM100 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C10W3TM100 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C10W3TM100 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C10W3TM100 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C10W3TM100 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

Current production — no lifecycle concerns for this BOM line.

The TM-D trip unit gives thermal overload protection (L) and fixed magnetic short-circuit protection (I) — no adjustment dials, so the trip curve is set at the factory. The 100 kA Icu at 690 V AC means this breaker can safely interrupt a fault current up to 100,000 A at that voltage without failing; that's an HB2 breaking capacity code, suited for high-fault installations like large distribution panels or industrial mains. The 3-pole (3P) configuration protects three phases; the device is category A (no intentional short-time delay), so it's for instantaneous tripping applications. Mounts on a backplate — not DIN-rail — so plan for screw-down installation in a panel. The 105 mm width, 161 mm height, and 86 mm depth fit standard ComPacT NSX cutouts. IP40 front face keeps out tools and wires >1 mm; IK07 impact rating handles a 2 J hammer blow.

Frequently asked questions

Where can I buy C10W3TM100 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

What is the breaking capacity of C10W3TM100?

100 kA Icu at 500 V AC, 100 kA Icu at 525 V AC, and 100 kA Icu at 660/690 V AC, all conforming to IEC 60947-2. That's the HB2 breaking capacity code.

What standards does C10W3TM100 comply with?

EN/IEC 60947-2 for low-voltage switchgear and controlgear. It also carries suitability for isolation per that standard, pollution degree 3 per IEC 60664-1, and overvoltage category III.

What is the trip unit type on C10W3TM100?

Thermal-magnetic TM-D trip unit: L protection for overload (thermal) and I protection for short-circuit (magnetic). Fixed settings, no adjustment.