Schneider Electric C10W32D100 — Miniature Circuit Breakers (MCB)

Schneider Electric C10W32D100 ComPacT NSX100HB2, 100 A, 100

MPNC10W32D100
Active

Schneider Electric ComPacT NSX series, NSX100HB2, 3-pole, 100 A at 40 °C, 100 kA Icu at 690 V AC, MicroLogic 2.2 electronic trip unit, LSoI protection.

$8.38Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

C10W32D100 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C10W32D100 — Ratings
ParameterValue
Rated current (In)100 A at 40 °C
Poles configuration3P
Breaking capacity100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C10W32D100 — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C10W32D100 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C10W32D100 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C10W32D100 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C10W32D100 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range40...100 A
Trip unit protection functionsLSoI

Product details

The Schneider Electric C10W32D100 is a ComPacT NSX100HB2 molded-case circuit breaker — 3-pole, 100 A frame, with a MicroLogic 2.2 electronic trip unit. For a 690 V distribution panel, that's serious SCCR headroom; you can coordinate downstream breakers without worrying about upstream failure. The trip unit is MicroLogic 2.2, an electronic design with three protection functions: L (long-time overload), So (short-time short-circuit with fixed delay), and I (instantaneous short-circuit). That matters for motor starting or repeated inrush loads. The breaker is also certified for isolation per EN/IEC 60947-2, meaning you can use it as a visible disconnect without a separate switch.

Where it fits and how it mounts

Mounts on a backplate in either horizontal or vertical orientation, flat against the surface. Front connections top and bottom — the 35 mm connection pitch matches standard busbar and cable lug spacing. IP40 enclosure protection means it's fine in a clean indoor panel; IK07 impact rating handles accidental tool drops.

Durability and electrical life

Electrical durability varies with load: 20,000 cycles at 440 V at half rated current, 10,000 cycles at full rated current at 440 V, and 5,000 cycles at 690 V at full current. For a distribution breaker that sees infrequent switching, that's ample.

Frequently asked questions

What is the breaking capacity of C10W32D100?

100 kA Icu at 500 V, 525 V, and 660/690 V AC 50/60 Hz per IEC 60947-2. That's the maximum fault current it can safely interrupt at those voltages.

What protection functions does the MicroLogic 2.2 trip unit provide?

L (long-time overload), So (short-time short-circuit with fixed delay), and I (instantaneous short-circuit). It's an electronic trip unit with thermal memory lasting 20 minutes before and after tripping.

What are the mounting dimensions of C10W32D100?

161 mm high, 105 mm wide, 86 mm deep. Mounts flat on a backplate in horizontal or vertical orientation. Front connections top and bottom with a 35 mm connection pitch.

Where can I buy C10W32D100 and what is the lead time?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for the latest lead time and price.

MPN
C10W32D100