Schneider Electric C25W32M220 — Miniature Circuit Breakers (MCB)

C25W32M220 ComPacT NSX250HB2, 220 A, 100 kA at 690 V

MPNC25W32M220
Active

Schneider Electric ComPacT NSX, NSX250HB2, motor-protection circuit breaker, 3P, 220 A, 100 kA Icu at 690 V AC, MicroLogic 2.2 M electronic trip unit.

$779.36Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C25W32M220 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationMotor protection
C25W32M220 — Ratings
ParameterValue
Rated current (In)220 A at 65 °C
Poles configuration3P
Breaking capacity100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C25W32M220 — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C25W32M220 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlashing LED (green) for ready to operate LED 95 % Ith (red) for temperature over set point
C25W32M220 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C25W32M220 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C25W32M220 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range100...220 A
Trip unit protection functionsLSoI

Product details

Motor-protection circuit breaker, 220 A, 100 kA Icu

The C25W32M220 is a ComPacT NSX250HB2 motor-protection circuit breaker from Schneider Electric's ComPacT NSX range, rated 220 A at 65 °C with a MicroLogic 2.2 M electronic trip unit. It delivers 100 kA Icu breaking capacity at 690 V AC 50/60 Hz per IEC 60947-2 — that is the fault-clearing capability at the full rated voltage, not a derated figure. The MicroLogic 2.2 M trip unit provides L (long-time overload), So (short-time short-circuit with fixed delay), and I (instantaneous short-circuit) protection curves, with selectable motor tripping classes 5, 10, and 20. That range covers standard motor start profiles from fast-ramping small motors (class 5) up to high-inertia loads like centrifuges or crushers (class 20).

The 35 mm connection pitch matches common distribution block and busbar patterns. IP40 front-face protection and IK07 impact resistance mean it is suited for enclosed panel installation where incidental contact and light mechanical shock are the main environmental risks — not washdown, not outdoor exposure.

Electrical durability and duty cycle

Rated for 20,000 mechanical cycles and 10,000 electrical cycles at full rated current (440 V, In). At half-load (In/2) the electrical endurance doubles to 20,000 cycles at 440 V, and at 690 V it is rated 5,000 cycles at full current and 10,000 at half-load. For a motor starter duty cycle — say one start per hour, 24/7 — that translates to roughly 2–4 years of electrical life before the contact tips need inspection, depending on the actual switching load and voltage.

Frequently asked questions

What is the breaking capacity of C25W32M220?

The C25W32M220 has a breaking capacity of 100 kA Icu at 500 V, 525 V, and 690 V AC 50/60 Hz per IEC 60947-2. That means it can safely interrupt a 100 kA fault at the full rated voltage without upstream protection needing to clear first.

What trip unit does C25W32M220 use?

It uses a MicroLogic 2.2 M electronic trip unit with L (long-time overload), So (short-time short-circuit with fixed delay), and I (instantaneous short-circuit) protection. Motor tripping classes 5, 10, and 20 are selectable.

Where can I buy C25W32M220 and get current pricing?

The C25W32M220 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
C25W32M220