Schneider Electric G12F4A32 — Miniature Circuit Breakers (MCB)

G12F4A32 GoPact MCCB 125, 32A 4P TM-D, 30kA 415V

MPNG12F4A32
Active

Schneider Electric GoPact MCCB 125, 4-pole thermal-magnetic circuit breaker, TM-D trip unit, 32 A rated current, 30 kA breaking capacity at 415 V AC, fixed mount, screw terminals, grey RAL 7035.

$109.20Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

G12F4A32 — Identification
ParameterValue
Product nameGoPact MCCB 125
Product range (series)GoPact MCCB
Product/component typeCircuit breaker
Device applicationDistribution
G12F4A32 — Ratings
ParameterValue
Rated current (In)32 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated insulation voltage (Ui)440 V AC conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Utilisation categoryCategory A
Overvoltage categoryIII
G12F4A32 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)8000 cycles at 415 V In
Mechanical durability (cycles)30000 cycles
G12F4A32 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
G12F4A32 — Environmental
ParameterValue
Operating ambient temperature-20...55 °C
Storage ambient temperature-35...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
G12F4A32 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H
G12F4A32 — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity30 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity15 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
G12F4A32 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.8...1 x In
Trip unit protection functionsLI

Product details

The TM-D trip unit gives you LI protection: thermal overload (L) for sustained overcurrents and magnetic short-circuit (I) for fast clearing of high faults.

This breaker mounts fixed to a backplate — no DIN-rail clip, so plan for screw-terminal lug landing on a busbar or cable. Both line and load connections are front-facing screw terminals with a 25 mm pitch, which keeps wiring neat in a row of breakers. At 100 mm wide × 130 mm tall × 60 mm deep, it fits standard distribution board cutouts.

The utilisation category A rating confirms it's not intended for motor starting duty (that would be category B with a dedicated magnetic-only trip), so keep it on feeder and sub-distribution circuits. The electrical durability of 8000 cycles at rated current and 415 V is typical for this class — fine for a panel that sees occasional switching, not for a daily disconnect application.

Frequently asked questions

What is the breaking capacity of G12F4A32?

The G12F4A32 has a 30 kA breaking capacity at 380/415 V AC (performance level F), certified per EN/IEC 60947-2.

What trip unit does G12F4A32 use?

It uses a TM-D thermal-magnetic trip unit with LI protection: thermal overload (L) and magnetic short-circuit (I). The trip unit rating is 32 A at 40 °C.

Where can I buy G12F4A32 and how is it quoted?

The G12F4A32 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation does G12F4A32 carry?

The G12F4A32 is certified to EN/IEC 60947-1, EN/IEC 60947-2, and EN/IEC 60947-2 Annex H. It is suitable for isolation per that standard. Pollution degree 3 and overvoltage category III are rated per IEC 60664-1.

MPN
G12F4A32