Skip to main content
Schneider Electric LC2K06015P7TQ — Contactors

Schneider TeSys K LC2K06015P7TQ Reversing Contactor, 6 A AC-

MPNLC2K06015P7TQ
Active

Schneider Electric TeSys K reversing contactor, LC2K06015P7TQ, 3-pole, AC-3 440V 6 A, coil 230 V AC 50/60 Hz, mechanically interlocked.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LC2K06015P7TQ — Identification
ParameterValue
Product / component typeReversing contactor
ApplicationMotor control
LC2K06015P7TQ — Ratings & Performance
ParameterValue
Utilisation categoryAC-3
LC2K06015P7TQ — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K06015P7TQ — Environmental
ParameterValue
IP degree of protectionIP2X conforming to VDE 0106
Operating altitude2000 m without derating
Protective treatment / pollution degreeTC conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC2K06015P7TQ — Approvals
ParameterValue
StandardsBS 5424 VDE 0660 NF C 63-110 IEC 60947
LC2K06015P7TQ — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

Reversing contactor for motor control

The Schneider Electric TeSys K LC2K06015P7TQ is a reversing contactor — two contactors in one package with a mechanical interlock, so only one set of poles closes at a time. That interlock prevents a phase-to-phase short when swapping the motor rotation direction. At 440 V AC that translates to roughly 3 kW of motor power, which is the typical rating for a small conveyor, pump, or fan. The control coil is 230 V AC 50/60 Hz, drawing about 1.3 W holding power. Drop-out voltage is below 0.20 Uc, so it releases reliably on a sagging line.

Compliant with BS 5424, VDE 0660, NF C 63-110, and IEC 60947. IP2X finger protection per VDE 0106.

Integration notes

Power and control connections are screw clamp terminals, accepting up to 4 mm² solid or flexible wire. Spring terminal and Faston versions also listed for the same base contactor. The mechanical interlock is built in, so no external wiring or logic is needed to prevent simultaneous closure. The auxiliary contact composition is 1 NC, which can be wired into the opposite contactor's coil circuit for an additional safety layer.

Frequently asked questions

What are the key ratings for this reversing contactor?

Rated 6 A in AC-3 at 440 V, with a 230 V AC 50/60 Hz control coil. Motor power capacity is up to 3 kW at 440/500 V AC.

What standards does this contactor comply with?

Compliant with BS 5424, VDE 0660, NF C 63-110, and IEC 60947. Also tested for 850 °C glow-wire resistance per IEC 60695-2-1.

What are the physical dimensions of the LC2K06015P7TQ?

Width 90 mm, height 58 mm, depth 57 mm.

MPN
LC2K06015P7TQ