Skip to main content
Schneider Electric LC2K06015D7 — Contactors

TeSys K LC2K06015D7 Reversing Contactor, 3P, 6 A AC-3, 42 VA

MPNLC2K06015D7
Obsolete

Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 6 A, 1 NC, 42 V AC coil, preassembled with reversing power busbar.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC2K06015D7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K06015D7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-4 AC-3
LC2K06015D7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K06015D7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K06015D7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric LC2K06015D7 is a TeSys K reversing contactor — 3 poles, rated AC-3 ≤440 V at 6 A, with a 42 V AC coil and one NC auxiliary contact. It comes preassembled with the reversing power busbar, so it's ready to wire into a motor-reversing circuit without extra bus work. The AC-3 rating (6 A at ≤440 V) means it's sized for switching squirrel-cage motors under full load — the standard duty cycle for starting, stopping, and reversing induction motors. The 42 V AC coil keeps control voltage low for safety in panel environments.

Mechanical and environmental robustness

The contactor withstands shocks up to 15 Gn on Y and Z axes (contactor closed) and 10 Gn on X axis, per IEC 60068-2-27. Vibration resistance is 4 Gn closed, 2 Gn opened across 5–300 Hz. Protective treatment conforms to IEC 60068 and DIN 50016 for humidity and corrosion resistance — relevant for panels in washdown or coastal environments.

Frequently asked questions

What replaces the LC2K06015D7?

Schneider Electric does not list an official direct successor order code for this part. A current-series reversing contactor (such as from the TeSys D or TeSys Deca range) would need to be selected based on your voltage, current, and coil requirements — the panel footprint and busbar arrangement may differ.

What are the key ratings for this contactor?

3-pole reversing contactor, AC-3 rated 6 A at ≤440 V, 42 V AC coil, one NC auxiliary contact. Preassembled with reversing power busbar. IP20 protection, operating temperature -25 °C to 50 °C.

How do I source this obsolete part?

Submit an RFQ — we source from our multi-distributor network and confirm availability and pricing before order placement. No stock or lead-time number is published for this obsolete line.

MPN