Skip to main content
Schneider Electric LC2K120047M72 — Contactors

Schneider TeSys K LC2K120047M72 changeover contactor, 4P, 22

MPNLC2K120047M72
Obsolete

Schneider Electric TeSys K LC2K120047M72 changeover contactor, 4P, 220-230 V AC 50/60 Hz coil, AC-1 resistive load, preassembled with reversing power busbar.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC2K120047M72 — Identification
ParameterValue
Product / component typeChangeover contactor
Series / rangeTeSys
ApplicationResistive load
LC2K120047M72 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz
Utilisation categoryAC-1
LC2K120047M72 — Contacts & Poles
ParameterValue
Pole configuration4P
LC2K120047M72 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K120047M72 — Approvals
ParameterValue
StandardsBS 5424 VDE 0660 NF C 63-110 IEC 60947
LC2K120047M72 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric TeSys K LC2K120047M72 is a 4-pole changeover contactor — a reversing contactor preassembled with the reversing power busbar, so it arrives ready to wire into a motor-reversing or source-transfer circuit without sourcing separate interlock kits or bus links. Rated for AC-1 utilisation category (resistive loads), it carries a conventional free-air thermal current Ith of 20 A at 50 Hz, with an average power-circuit impedance of 3 mOhm per pole — heat dissipation is 1.3 W, which matters for enclosure sizing when several contactors sit side by side on a DIN rail.

Rated breaking capacity: 110 A at 440 V, 80 A at 500 V, 70 A at 660-690 V per IEC 60947 — this is the fault-clearing ability, not the continuous rating. Rated insulation voltage Ui is 690 V per IEC 60947-4-1 and 600 V per UL 508 / CSA C22.2 No 14 — the contactor is suitable for 480 V and 600 V class panels, but the UL listing caps the insulation at 600 V. Mechanical durability is 5 million cycles; electrical durability is 300,000 cycles at 20 A AC-1 at Ue ≤ 440 V. The B10d safety reliability figure is 1,369,863 cycles under nominal load per EN/ISO 13849-1 — relevant if this contactor is used in a safety-related stop circuit.

Mounts on plate or rail (DIN rail compatible). Connections are Faston terminals: accepts two 2.8 mm busbar tabs or one 6.35 mm tab per pole. The preassembled reversing busbar means the power wiring between the two contactor halves is already in place — just land the line and load connections. Operating altitude 2000 m without derating; overvoltage category III — standard for fixed-installation distribution panels.

Compliance: designed to BS 5424, VDE 0660, NF C 63-110, and IEC 60947. Flame retardance V1 per UL 94. Protective treatment TC per IEC 60068 and DIN 50016. The contactor carries the relevant certifications for European and North American panel builds.

Frequently asked questions

What are the key ratings for this contactor?

4-pole changeover contactor, AC-1 rated at 20 A Ith, 220-230 V AC 50/60 Hz coil, rated breaking capacity 110 A at 440 V, rated insulation voltage 690 V per IEC 60947-4-1, mechanical durability 5 million cycles.

What compliance standards does this contactor meet?

Designed to BS 5424, VDE 0660, NF C 63-110, IEC 60947. Flame retardance V1 per UL 94. Protective treatment TC per IEC 60068 and DIN 50016. IP20 finger protection per VDE 0106.

What is the physical size of this contactor?

90 mm wide, 58 mm high, 57 mm deep. Mounts on plate or DIN rail.

MPN