Skip to main content
Schneider Electric LC2K120045B7

Schneider Electric LC2K120045B7

MPNLC2K120045B7
Obsolete

TeSys K changeover contactor, 4P, AC,1 <= 440 V 20 A, 24 V AC coil

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC2K120045B7 key specifications
ParameterValue
Interlocking typeMechanical
Control circuit typeAC 50/60 Hz
Product or component typeChangeover contactor
Coil voltage24 V AC 50/60 Hz
VoltagePower circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA C22.2 No 14
Control circuit voltage limitsOperational: 0.8...1.15 Uc (at Drop-out: 0.2...0.75 Uc (at <122 °F (50 °C))
[Ue] rated operational voltagePower circuit 690 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Icw] rated short-time withstand current115 A 122 °F (50 °C) - 1 s for power circuit 105 A 122 °F (50 °C) - 5 s for power circuit 100 A 122 °F (50 °C) - 10 s for power circuit 75 A 122 °F (50 °C) - 30 s for power circuit 55 A 122 °F (50 °C) - 1 min for power circuit 50 A 122 °F (50 °C) - 3 min for power circuit 25 A 122 °F (50 °C) - >= 15 min for power circuit
Breaking capacity110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947
[Ie] rated operational current20 A (at 16 A (at <158 °F (70 °C)) at 690 V AC AC-1 for power circuit
[Ith] conventional free air thermal current20 A (at 122 °F (50 °C)) for power circuit

All specifications

LC2K120045B7 additional specifications
ParameterValue
Inrush power in30 VA (at 68 °F (20 °C))
Power pole contact composition4 NO
Hold-in power consumption in4.5 VA (at 68 °F (20 °C))
Poles description4P
Utilisation categoryAC-1
IP degree of protectionIP20 VDE 0106
Mounting supportRail Plate
Connections - terminalssolder pins 1.5 x 0.9 mm
Operating altitude6561.68 ft (2000 m) without derating
Depth2.2 in (57 mm)
Width3.5 in (90 mm)
Height2.3 in (58 mm)
Electrical durability0.3 Mcycles 20 A AC-1 <= 440 V
Mechanical durability5 Mcycles
StandardsVDE 0660 IEC 60947 NF C 63-110 BS 5424
RangeTeSys
Category22327-CTR,K-LINE,AC,OPEN,REV
Operating time10...20 ms coil energisation and NO closing 10...20 ms coil de-energisation and NO opening
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
Heat dissipation1.3 W
Average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Device short nameLC2K
Device applicationControl
Device presentationPreassembled with reversing power busbar
Overvoltage categoryIII
Protective treatmentTC IEC 60068 TC DIN 50016
Contactor applicationResistive load
Mechanical robustnessShocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
Associated fuse rating25 A gG at 25 A aM for power circuit
Maximum operating rate3600 cyc/h
Safety reliability levelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Irms rated making capacity144 A at 690 V AC for power circuit conforming to NF C 63-110 144 A at 690 V AC for power circuit conforming to IEC 60947
Ambient air temperature for storage-58...176 °F (-50...80 °C)
Ambient air temperature for operation-13...122 °F (-25...50 °C)
MPN