Schneider Electric LC2K1210C72 — Contactors

TeSys K LC2K1210C72 reversing contactor, 3P, 12 A AC-3, 36 V

MPNLC2K1210C72
Active

Schneider Electric TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NO, 36 V AC coil, preassembled with reversing power busbar.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LC2K1210C72 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationResistive load Motor control
LC2K1210C72 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-4 AC-1 AC-3
LC2K1210C72 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K1210C72 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K1210C72 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The LC2K1210C72 is a TeSys K reversing contactor from Schneider Electric — a 3-pole, 36 V AC coil unit rated 12 A in AC-3 duty at 440 V, with one normally-open auxiliary contact. The utilisation categories cover AC-1 (resistive), AC-3 (squirrel-cage motor start/run), and AC-4 (plugging/inching), so it handles both motor control and resistive loads. It ships preassembled with the reversing power busbar, which saves panel-build time versus wiring two contactors and a mechanical interlock separately.

For resistive loads (AC-1), the thermal current is higher, but the AC-3 figure is the one that decides motor fit. The 36 V AC coil is a control-circuit voltage common in older industrial plants and some rail applications; verify your control transformer matches before wiring. IP20 finger-safe terminals (per VDE 0106) mean it is intended for enclosure mounting, not exposed installation.

The preassembled reversing busbar eliminates the need to wire a separate interlock between two contactors, reducing wiring errors and panel fill time. The 3 NO power poles and single NO auxiliary contact are fixed; if you need additional auxiliaries, they must be added externally via the TeSys K auxiliary contact blocks.

Frequently asked questions

What is the rated operational voltage for the power circuit?

The power circuit is rated 690 V AC at 50/60 Hz. The AC-3 motor-switching rating is 12 A at 440 V.

What compliance documentation is available for this part?

The contactor carries IP20 protection per VDE 0106, flame retardance V1 per UL 94, and meets NF F 16-101 and NF F 16-102 for rail applications. Protective treatment conforms to IEC 60068 and DIN 50016.

MPN
LC2K1210C72