The Schneider Electric LV481 Molded Case Breakers Series series groups 12 related part numbers, each listed with full specifications, a datasheet where available, and an RFQ option. The listed variants share a common application of Equipment protection, monitoring and control Distribution, main product or component type of Switch-disconnector-fuse and operating temperature of -20...70 °C. Variants differ by depth, electrical life cycles and fuse type, so you can match the exact depth your application requires using the selection guide below.

Select a variant by

Depth
87 mm · 116 mm · 250 mm · 289 mm
Electrical life cycles
AC-22 A: 100 cycles 415 V AC 50/60 Hz AC-22 A: 100 cycles 690 V AC 50/60 Hz · AC-22 A: 100 cycles 415 V AC 50/60 Hz AC-22 A: 100 cycles 690 V AC 50/60 Hz AC-23 A: 100 cycles 415 V AC 50/60 Hz · AC-22 A: 1000 cycles 415 V AC 50/60 Hz AC-23 A: 1000 cycles 415 V AC 50/60 Hz AC-22 A: 1000 cycles 690 V AC 50/60 Hz AC-23 A: 1000 cycles 690 V AC 50/60 Hz · AC-22 A: 1500 cycles 415 V AC 50/60 Hz AC-23 A: 1500 cycles 415 V AC 50/60 Hz AC-22 A: 1500 cycles 690 V AC 50/60 Hz AC-23 A: 1500 cycles 690 V AC 50/60 Hz
Fuse type
DIN · NFC
Height
118 mm · 162 mm · 300 mm
Mechanical life cycles
5000 cycles · 10000 cycles
Width
148 mm · 184 mm · 458 mm · 562 mm

Shared specifications

Application
Equipment protection, monitoring and control Distribution
Main product or component type
Switch-disconnector-fuse
Operating temperature
-20...70 °C
Pollution degree
3 conforming to IEC 60947
Storage temperature
-40...80 °C
Temp operating max
70 °C
Temp operating min
-20 °C
Temp storage max
80 °C
Temp storage min
-40 °C

Variant comparison

ParameterLV481464LV481474LV481514LV481524
Depth250 mm289 mm87 mm116 mm
Electrical life cyclesAC-22 A: 100 cycles 415 V AC 50/60 Hz AC-22 A: 100 cycles 690 V AC 50/60 HzAC-22 A: 100 cycles 415 V AC 50/60 Hz AC-22 A: 100 cycles 690 V AC 50/60 Hz AC-23 A: 100 cycles 415 V AC 50/60 HzAC-22 A: 1500 cycles 415 V AC 50/60 Hz AC-23 A: 1500 cycles 415 V AC 50/60 Hz AC-22 A: 1500 cycles 690 V AC 50/60 Hz AC-23 A: 1500 cycles 690 V AC 50/60 HzAC-22 A: 1000 cycles 415 V AC 50/60 Hz AC-23 A: 1000 cycles 415 V AC 50/60 Hz AC-22 A: 1000 cycles 690 V AC 50/60 Hz AC-23 A: 1000 cycles 690 V AC 50/60 Hz
Fuse typeDINDINNFCNFC
Height300 mm300 mm118 mm162 mm
Mechanical life cycles5000 cycles5000 cycles10000 cycles10000 cycles
Width458 mm562 mm148 mm184 mm