ABB 2CCS400900R0011 neutral disconnector, 400 V rated voltage, 9 mm width, Circuit Breaker Accessories series.
Circuit Breaker, Miniature, DIN Rail Mount, 10A, 1P, 60VDC|Circuit Breaker, Miniature, DIN Rail Mount, 10 Amp, 1 Pole, 60 Volt DC, K Trip
Circuit Breaker, Miniature, DIN Rail Mount, 2A, 1P, 60VDC|Circuit Breaker, Miniature, DIN Rail Mount, 2 Amp, 1 Pole, 60 Volt DC, K Trip
Circuit Breaker, Miniature, DIN Rail Mount, 20A, 1P, 60VDC|Circuit Breaker, Miniature, DIN Rail Mount, 20 Amp, 1 Pole, 60 Volt DC, K Trip
Circuit Breaker, Miniature, DIN Rail Mount, 3A, 1P, 60VDC|Circuit Breaker, Miniature, DIN Rail Mount, 3 Amp, 1 Pole, 60 Volt DC, K Trip
Circuit Breaker, Miniature, DIN Rail Mount, 6A, 1P, 60VDC|Circuit Breaker, Miniature, DIN Rail Mount, 6 Amp, 1 Pole, 60 Volt DC, K Trip
Circuit Breaker, Miniature, DIN Rail Mount, 1A, 1P, 60VDC|1 Pole, 1 Amp Rated At 480y/277 Vac, Ul 489 Series Miniature Circuit Breaker With Thermal-magnetic Trip Device, Z Trip Curve
Circuit Breaker, Miniature, DIN Rail Mount, 2A, 1P, 60VDC|Circuit Breaker, Miniature, DIN Rail Mount, 2 Amp, 1 Pole, 60 Volt DC, Z Trip
Circuit Breaker, Miniature, DIN Rail Mount, 20A, 1P, 480Y/277VAC|ABB S201up-k20 1 Pole, 20 Amps Rated At 480y/277 Vac, Ul 489 Series Miniature Circuit Breaker With Thermal-magnetic Trip Device
Circuit Breaker, 150A, 3P|Circuit Breaker, Voltage Rating: 480/500 Volts AC/DC, Amperage Rating: 150 Amp, Trip Range: 1500 Amp, Frequency Rating: 50 - 60 Hz, Frame: 225 Amp, Trip Type: Thermal-Magnetic, Interrupt Rating: 35 Kamp at 480 Volts AC, Number of Poles: 3, Length: 4.130 Inch, Width: 2.760 Inch, Height: 5.90...
Circuit Breaker with Trip Unit, 600V, 300A|Circuit Breaker, Molded Case, 3-Pole, 300 Amp, Electronic Trip Unit, Voltage Rating: 600 Vac, Frequency Rating: 50 - 60 Hz,Trip Type: LS/I (ac Only), Pr221, Electronic, Interrupt Rating: 25 Kamp at 480 Vac, Mechanical Life: 20000 Operations, Weight: 8.550 Lb, Interrupting R...
Circuit Breaker, 600V, 400A|Circuit Breaker with Trip Unit, Voltage Rating: 600 Vac, Amperage Rating: 400 Amp, Frequency Rating: 50 - 60 Hz, Frame: 400 Amp, Trip Type: Ls/i (ac Only), Pr221, Electronic, Interrupt Rating: 25 Kamp at 480 Vac, Number of Poles: 3, Accessories Included: Auxiliary Switch, Weight: 8.550 Lb...
Circuit Breaker, 400A, 3P|Circuit Breaker, T5N Frame, Molded Case, 400 Amp, 3-Pole, Thermal-Magnetic
Circuit Breaker, 400A, 3P|Circuit Breaker, Voltage Rating: 600 Vac/Vdc, Amperage Rating: 400 Amp, Frequency Rating: 50 - 60 Hz, Frame: 300 - 400 Amp, Trip Type: Thermal-Magnetic, Trip Range: 2000 - 4000 Amp, Interrupt Rating: 25 Kamp at 480 Vac, Number of Poles: 3, Length: 5.510 Inch, Width: 470 Inch, Height: 870 In...
Circuit Breaker, 400A, 3P|Circuit Breaker, Voltage Rating: 600 Volts AC/DC, Amperage Rating: 400 Amp, Frequency Rating: 50 - 60 Hz, Frame: 300 - 400 Amp, Trip Type: Thermal-Magnetic, Trip Range: 2000 - 4000 Amp, Interrupt Rating: 35 Kamp at 480 Volts AC, Number of Poles: 3, Length: 5.510 Inch, Width: 470 Inch, Heigh...
Circuit Breaker, 600A, 600V|Circuit Breaker, Amperage Rating: 600 Amp, Voltage Rating: 600 Vac, Frequency Rating: 50 - 60 Hz, Frame: 600 Amp, Interrupt Rating: 35 Kamp at 480 Vac, Number of Poles: 3, Length: 8.260 Inch, Width: 470 Inch, Height: 10.550 Inch, Interrupting Rating Class/Breaking Capacity: Normal, Mechan...
Circuit Breaker, 600A, 3P|Circuit Breaker, Amperage Rating: 600 Amp, Voltage Rating: 600 Vac/Vdc, Frequency Rating: 50 - 60 Hz, Frame: 600 Amp, Trip Type: Thermal-Magnetic, Trip Range: 3000 - 6000 Amp, Interrupt Rating: 35 Kamp at 480 Vac, Number of Poles: 3, Length: 8.260 Inch, Width: 470 Inch, Height: 10.550 Inch,...
Circuit Breaker, 600A, 3P|Circuit Breaker, Amperage Rating: 600 Amp, Voltage Rating: 600 Volts AC/DC, Frequency Rating: 50 - 60 Hz, Frame: 600 Amp, Trip Type: Thermal-Magnetic, Trip Range: 3000 - 6000 Amp, Interrupt Rating: 50 Kamp at 480 Volts AC, Number of Poles: 3, Length: 8.260 Inch, Width: 4.70 Inch, Height: 10...
BUS PLUG C/B 100A 600V 3P|Siemens Low Voltage Busway BD Busway Plugs - BD BW CB PL 3PH3W 125 Amp are Power Distribution Busway. Sub Brand BD BW Plugs Circuit Breaker Type BD Plug-In Application Busway Standard UL Number Of Wires 3W Phase 3PH NEMA Rating IP40 Consist Of Enclosure Only
BUS PLUG C/B 100A 600V 4P|Siemens Low Voltage Busway BD Busway Plugs - BD BW CB PL 3PH4W 100pct Ntrl 125 Amp are Power Distribution Busway. Sub Brand BD BW Plugs Circuit Breaker Type BDPlug-In Application Busway Standard UL Number Of Wires 4W Phase 3PH NEMA RatingIP40 Consist Of Enclosure Only
Panel Board, 100A, Main Breaker, 12/24 Circuit, 1PH, 100kAIC, NEMA 1|Panel Board, 100 Amp, Main Breaker, 12 Space, 24 Circuit, 120/240 Volt AC, 100 kAIC, 1-Phase NEMA 1
BRKR LD6 3P 600V 600A LI|SIEMENS LOW VOLTAGE SENTRON MOLDED CASE CIRCUIT BREAKER WITH SOLID STATE SENSITRIP III ELECTRONIC TRIP UNIT. ASSEMBLED STANDARD 40 DEG C BREAKER LD FRAME WITH STANDARD BREAKING CAPACITY. 600A 3-POLE (25KAIC AT 600V) (35KAIC AT 480V). NON-INTERCHANGEABLE LI TRIP UNIT. SPECIAL FEATURES NO LUGS...
BRKR JD/LD 2/3P AL BODY LUG 2W 500KCMIL|SIEMENS LOW VOLTAGE SENTRON MOLDED CASE CIRCUIT BREAKER ACCESSORY. ALUMINUM BODY LUG FOR 2/3-POLE 200A - 400A JD AND LD FRAME BREAKER. WIRE RANGE 3/0AWG - 500KCMIL (CU) / 4/0AWG - 500KCMIL (AL) - 2 BARREL LUG. SUITABLE FOR LINE AND LOAD SIDES. SINGLE LUG.
CIRCUIT BREAKER THERMAL MAGNETIC 3POLE 60A 690VAC/250VDC|CIRCUIT BREAKER THERMAL MAGNETIC 3POLE 60A 690VAC/250VDC
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LIN In=80A rated current IR=63...80A overload protection II=400...800A, short-circuit protection N conductor protected without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LI In=160A rated current IR=125...160A overload prot. II=800...1600A, short-circuit protection N conductor unprotected without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LIN In=160A rated current IR=160A overload protection II=640A, short-circuit prot. N conductor protected without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=100A rated current IR=80...100A overload prot. II=500...1000A, short-circuit protection without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=160A rated current IR=160A overload protection II=640A, short-circuit prot. without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LIN In=125A rated current IR=100...125A overload prot. II=625...1250A, short-circuit protection N conductor protected without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LI In=50A rated current IR=40...50A overload protection II=250...500A, short-circuit protection N conductor unprotected without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LI In=160A rated current IR=160A overload protection II=640A, short-circuit prot. N conductor unprotected without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=32A rated current IR=25...32A overload protection II=160...320A, short-circuit protection without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=100A rated current IR=100A overload protection II=400A, short-circuit prot. without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, motor protection trip unit TM, LI In=100A rated current IR=80...100A overload prot. II=1000A, short-circuit prot. without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=80A rated current IR=63...80A overload protection II=400...800A, short-circuit protection without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=125A rated current IR=125A overload protection II=500A, short-circuit prot. without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=125A rated current IR=100...125A overload prot. II=625...1250A, short-circuit protection without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LI In=50A rated current IR=50A overload protection II=200A, short-circuit prot. N-conductor unprotected without auxiliary release without auxiliary/alarm switch with front terminals
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, starter combination trip unit TM, LIN In=160A rated current II=800...1600A, short-circuit protection without auxiliary release without auxiliary/alarm switch with front terminals
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LI In=100A rated current IR=80...100A overload prot. II=500...1000A, short-circuit protection N conductor unprotected without auxiliary release without auxiliary/alarm switch with front terminals