ARGUS-M DIRECTIONAL OVERCURRENT RELAY CASE SIZE E8,5 CT,4 VT,16 LEDS 13 BINARY INP./ 14 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ AUXILIARY VOLTAGE: 30 TO 220V DC, BINARY INPUT THRESHOLD 19V DC USB FRONT PORT, RS485 REAR PORT PLUS REAR ELECTR.ETHERNET RJ45 PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER...
ARGUS Non-directional overcurrent-time protection Polycarbonate enclosure, 4x current transformer, 2 BI/2 BQ, pulse output, 9 LEDs Measuring input: 5 A, 50/60 Hz Auxiliary voltage: current transformer supplied USB front interface No protocol (no interface on the rear) Device front: standard version Protection functi...
ARGUS Non-directional overcurrent-time protection Polycarbonate enclosure, 4x current transformer, 2 BI/2 BQ, pulse output, 9 LEDs Measuring input: 1 A, 50/60 Hz Auxiliary voltage: current transformer supplied USB front interface No protocol (no interface on the rear) Device front: standard version Protection functi...
ARGUS-C DIRECT. OVERCURRENT RELAY E4 CASE, 1 CT, 10 LEDS, 3 BINARY INPUTS/ 5 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ WITH SEF INPUT AUXILIARY VOLTAGE: 80 TO 250V DC, BINARY INPUT THRESHOLD 88V DC USB FRONT PORT, RS485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTI...
ARGUS-C DIRECT. OVERCURRENT RELAY E4 CASE, 4 CT, 10 LEDS, 6 BINARY INPUTS/ 8 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ AUXILIARY VOLTAGE: 80 TO 250V DC, 115V AC BINARY INPUT THRESHOLD 19V DC USB FRONT PORT, RS485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) FRO...
ARGUS-C DIRECT. OVERCURRENT RELAY E4 CASE, 4 CT, 10 LEDS, 3 BINARY INPUTS/ 5 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ AUXILIARY VOLTAGE: 80 TO 250V DC, BINARY INPUT THRESHOLD 88V DC USB FRONT PORT, RS485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) FRONT COVER...
ARGUS-C DIRECT. OVERCURRENT RELAY E4 CASE, 4 CT, 10 LEDS, 3 BINARY INPUTS/ 5 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ WITH SEF INPUT AUXILIARY VOLTAGE: 80 TO 250V DC, BINARY INPUT THRESHOLD 88V DC USB FRONT PORT, RS485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTI...
ARGUS-C DIRECT. OVERCURRENT RELAY E4 CASE, 4 CT, 10 LEDS, 3 BINARY INPUTS/ 5 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ AUXILIARY VOLTAGE: 80 TO 250V DC, 115V AC BINARY INPUT THRESHOLD 19V DC USB FRONT PORT, RS485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) FRO...
ARGUS-M DIRECTIONAL OVERCURRENT RELAY CASE SIZE E8,5 CT,4 VT,16 LEDS 13 BINARY INP./ 14 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ AUXILIARY VOLTAGE: 30 TO 220V DC, BINARY INPUT THRESHOLD 88V DC USB FRONT PORT, RS485 REAR PORT PLUS REAR ELECTR.ETHERNET RJ45 PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER...
ARGUS-C DIRECT. OVERCURRENT RELAY E4 CASE, 4 CT, 10 LEDS, 6 BINARY INPUTS/ 8 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ AUXILIARY VOLTAGE: 80 TO 250V DC, BINARY INPUT THRESHOLD 88V DC USB FRONT PORT, RS485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) FRONT COVER...
ARGUS-C DIRECT. OVERCURRENT RELAY E4 CASE, 4 CT, 10 LEDS, 6 BINARY INPUTS/ 8 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ AUXILIARY VOLTAGE: 80 TO 250V DC, 115V AC BINARY INPUT THRESHOLD 19V DC USB FRONT PORT, RS485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) FRO...
ARGUS-C DIRECT. OVERCURRENT RELAY E4 CASE, 4 CT, 10 LEDS, 6 BINARY INPUTS/ 8 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ AUXILIARY VOLTAGE: 80 TO 250V DC, BINARY INPUT THRESHOLD 88V DC USB FRONT PORT, RS485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3 (USER SELECTABLE SETTING) FRONT COVER: ...
ARGUS-C NON DIRECT. OVERCURRENT RELAY E4 CASE, 4 CT, 10 LEDS, 3 BINARY INPUTS/ 5 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ AUXILIARY VOLTAGE: 80 TO 250V DC, BINARY INPUT THRESHOLD 88V DC USB FRONT PORT, RS485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) FRONT C...
ARGUS-C NON DIRECT. OVERCURRENT RELAY 4 CT, 10 LEDS, 6 BINARY INPUTS/ 8 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ AUXILIARY VOLTAGE: 80 TO 250V DC, BINARY INPUT THRESHOLD 88V DC USB FRONT PORT, RS485 REAR PORT PLUS REAR OPTIC.ETHERNET DUPLEX (E6 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 AND IEC 61...
ARGUS-C NON DIRECT. OVERCURRENT RELAY E4 CASE, 4 CT, 10 LEDS, 6 BINARY INPUTS/ 8 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ WITH SEF INPUT AUXILIARY VOLTAGE: 80 TO 250V DC, 115V AC BINARY INPUT THRESHOLD 19V DC USB FRONT PORT, RS485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELE...
ARGUS-C NON DIRECT. OVERCURRENT RELAY E4 CASE, 4 CT, 10 LEDS, 6 BINARY INPUTS/ 8 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ AUXILIARY VOLTAGE: 80 TO 250V DC, 115V AC BINARY INPUT THRESHOLD 19V DC USB FRONT PORT, RS485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING)...
ARGUS-C NON DIRECT. OVERCURRENT RELAY E4 CASE, 4CT, 10LEDS, 3 BINARY INPUTS/ 5 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ AUXILIARY VOLTAGE: 80 TO 250V DC/ 115V AC, BINARY INPUT THRESHOLD 19V DC USB FRONT PORT, RS485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP3.0 (USER SELECTABLE SETTING) F...
ARGUS-C NON DIRECT. OVERCURRENT RELAY 4 CT, 10 LEDS, 6 BINARY INPUTS/ 8 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ AUXILIARY VOLTAGE: 80 TO 250V DC, BINARY INPUT THRESHOLD 88V DC USB FRONT PORT, RS485 REAR PORT PLUS REAR ELECTRI.ETHERNET RJ45 (E6 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 AND IEC 61...
ARGUS-C NON DIRECT. OVERCURRENT RELAY E4 CASE, 1 CT, 10 LEDS, 3 BINARY INPUTS/ 5 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ AUXILIARY VOLTAGE: 80 TO 250V DC, BINARY INPUT THRESHOLD 88V DC USB FRONT PORT, RS485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) FRONT C...
ARGUS-C DIRECT. OVERCURRENT RELAY 4 CT, 10 LEDS, 6 BINARY INPUTS/ 8 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ WITH SEF INPUT AUXILIARY VOLTAGE: 80 TO 250V DC, BINARY INPUT THRESHOLD 88V DC USB FRONT PORT, RS485 REAR PORT PLUS REAR ELECTR.ETHERNET RJ45 (E6 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 ...
ARGUS-C NON DIRECT. OVERCURRENT RELAY E4 CASE, 4 CT, 10 LEDS, 6 BINARY INPUTS/ 8 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ AUXILIARY VOLTAGE: 80 TO 250V DC BINARY INPUT THRESHOLD 88V DC USB FRONT PORT, RS485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) FRONT CO...
Omron G6B series general-purpose relay, 4PST contact form, 24V DC coil, 2 A contact rating at 250V AC / 30V DC, PCB-mount 4-pin package.
Transformer protection (2 wdg.) 8 curr. trans., 16 BI, 8 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces S12 enclosure
Transformer protection (3 windings) 12 Current tr., 3 AFD (Arc Flash Detector) 24 BI, 13 BO (incl. 3 HSBO) Standard interface: 1 x USB (front), RS485 (rear) + 2 x optical LC-interfaces S12 enclosure
Transformer protection (2 wdg.) 8 curr. trans., 16 BI, 8 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x optical LC interf. S12 enclosure
Transformer prot. 7SR54 8 curr. trans., 4 volt. trans., 22 BI, 12 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces, S12 enclosure
Transformer protection (2 wdg.) 8 curr. trans., 4 volt. trans. 37 BI, 18 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces S12 enclosure incl. conformal coating
7SX800 universal protection device; with basic functionality; function extension through additionally orderable function points; BI: 14; BO: 11 (10 fast, 1 life); I: 4 (3 x protection, 1x sensitive); U: 4 (standard); housing: 1/6 x 19''; 8 LEDs; 9 function keys; Ethernet: optical; serial interface; operation panel: ...
Directional time-overcurrent protection 7SR51 4 curr. trans., 4 volt. trans., 24 BI, 14 BO Standard interface: 1 x USB (front), RS485 (rear) + 2 x RJ45 interfaces, S12 enclosure
Overcurrent time protection 7SR51 4 curr. trans., 23 BI, 12 BQ Standard interface: 1 x USB (front), RS485 (rear) + 2 x RJ45 interfaces S12 enclosure
Directional time-overcurrent protection 7SR51 4 curr. trans., 4 volt. trans., 9 BI, 8 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces S6 enclosure
Directional time-overcurrent protection 7SR51 4 curr. trans., 4 volt. trans., 9 BI, 8 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x optical LC interf. S6 enclosure
Directional time-overcurrent protection 7SR51 4 curr. trans., 4 volt. trans., 39 BI, 20 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces S12 enclosure
Directional time-overcurrent protection 7SR51 4 curr. trans., 4 volt. trans., 14 BI, 10 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces S12 enclosure
Directional time-overcurrent protection 7SR51 4 curr. trans., 4 volt. trans., 19 BI, 12 BQ Standard interface: 1 x USB (front), RS485 (rear) + 2 x RJ45 interfaces S12 enclosure
Directional time-overcurrent protection 7SR51, 4 curr. trans., 4 volt. trans., 24 BI, 14 BO Standard interface: 1 x USB (front), RS485 (rear) + 2 x RJ45 interfaces, S12 enclosure, including conformal coating
Directional time-overcurrent protection 7SR51 4 curr. trans., 4 volt. trans., 39 BI, 20 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x optical LC interf. S12 enclosure
Directional time-overcurrent protection 7SR51 4 curr. trans., 4 volt. trans., 14 BI, 10 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x optical LC interf. S12 enclosure
Overcurrent time protection 7SR51 4 curr. trans., 23 BI, 12 BQ Standard interface: 1 x USB (front), RS485 (rear) + 2 x optical LC interf. S12 enclosure
Overcurrent time protection 7SR51, 4 curr. trans., 8 BI, 6 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces, S6 enclosure, including conformal coating
7SX800 universal protection device; contains 100 function points; BI: 14; BO: 11 (10 fast, 1 life); I: 4 (3 x protection, 1x sensitive); U: 4 (standard); housing: 1/6 x 19''; 8 LEDs; 9 function keys; Ethernet: optical; serial interface; operation panel: integrated; display type: color display; front design: standard...
Overcurrent time protection 7SR51 4 curr. trans., 8 BI, 6 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces S6 enclosure
Directional time-overcurrent protection 7SR51,5 curr. trans., 4 volt. trans., 22 BI, 12 BO, Standard interface: 1 x USB (front), RS 485 (rear) + 2 x optical LC-interfaces, S12 enclosure
Directional time-overcurrent protection 7SR51,5 curr. trans., 4 volt. trans., 22 BI, 12 BO, Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces S12 enclosure