circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LIN In=80A rated current IR=63...80A overload protection II=400...800A, short-circuit protection N conductor protected without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LI In=160A rated current IR=125...160A overload prot. II=800...1600A, short-circuit protection N conductor unprotected without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LIN In=160A rated current IR=160A overload protection II=640A, short-circuit prot. N conductor protected without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=100A rated current IR=80...100A overload prot. II=500...1000A, short-circuit protection without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=160A rated current IR=160A overload protection II=640A, short-circuit prot. without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LIN In=125A rated current IR=100...125A overload prot. II=625...1250A, short-circuit protection N conductor protected without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=32A rated current IR=25...32A overload protection II=160...320A, short-circuit protection without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=100A rated current IR=100A overload protection II=400A, short-circuit prot. without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=80A rated current IR=63...80A overload protection II=400...800A, short-circuit protection without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=125A rated current IR=125A overload protection II=500A, short-circuit prot. without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=125A rated current IR=100...125A overload prot. II=625...1250A, short-circuit protection without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LI In=50A rated current IR=50A overload protection II=200A, short-circuit prot. N-conductor unprotected without auxiliary release without auxiliary/alarm switch with front terminals
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, starter combination trip unit TM, LIN In=160A rated current II=800...1600A, short-circuit protection without auxiliary release without auxiliary/alarm switch with front terminals
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LI In=100A rated current IR=80...100A overload prot. II=500...1000A, short-circuit protection N conductor unprotected without auxiliary release without auxiliary/alarm switch with front terminals
circuit breaker 3VT3 standard breaking capacity Icu=36kA, 415V AC 4-pole; circuit breaker w/o Electronic Trip Unit N connected+measured without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT2 high breaking capacity Icu=65kA, 415V AC 4-pole; circuit breaker w/o Electronic Trip Unit N connected+measured without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT2 standard breaking capacity Icu=36kA, 415V AC 4-pole; circuit breaker w/o Electronic Trip Unit N connected without auxiliary release without auxiliary/alarm switch
SWITCH DISCONNECTOR 3VT3 STANDARD BREAKING CAPACITY ICU=36KA, 415V AC 4-POLE; SWITCH DISCONNECTOR W/O OVERLOAD PROTECTION W/O SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
SWITCH DISCONNECTOR 3VT2 HIGH BREAKING CAPACITY ICU=65KA, 415V AC 4-POLE; SWITCH DISCONNECTOR W/O OVERLOAD PROTECTION W/O SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH IRM= 4 X IR,
switch disconnector 3VT2 high breaking capacity Icu=65kA, 415V AC 3-pole; switch disconnector no overload protection no short-circuit protection without auxiliary release without auxiliary/alarm switch IRM=4 xIR
switch disconnector 3VT3 standard breaking capacity Icu=36kA, 415V AC 3-pole; switch disconnector no overload protection no short-circuit protection without auxiliary release without auxiliary/alarm switch
switch disconnector 3VT2 standard breaking capacity Icu=36kA, 415V AC 3-pole; switch disconnector no overload protection no short-circuit protection without auxiliary release without auxiliary/alarm switch
switch disconnector 3VT5 high breaking capacity Icu=65kA, 415V AC 3-pole; switch disconnector no overload protection no short-circuit protection without auxiliary release without auxiliary/alarm switch
switch disconnector 3VT3 high breaking capacity Icu=65kA, 415V AC 3-pole; switch disconnector no overload protection no short-circuit protection without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT3 standard breaking capacity Icu=36kA, 415V AC 3-pole; circuit breaker w/o Electronic Trip Unit without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT2 standard breaking capacity Icu=36kA, 415V AC 3-pole; circuit breaker w/o Electronic Trip Unit without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LI In=160A rated current IR=125...160A overload prot. II=800...1600A, short-circuit protection N conductor unprotected without auxiliary release without auxiliary/alarm switch with front terminals
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=80A rated current IR=80A overload protection II=320A, short-circuit prot. without auxiliary release without auxiliary/alarm switch with front terminals
circuit breaker 3VT3 high breaking capacity Icu=65kA, 415V AC 3-pole; circuit breaker w/o Electronic Trip Unit without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT2 high breaking capacity Icu=65kA, 415V AC 4-pole; circuit breaker w/o Electronic Trip Unit N connected without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT2 standard breaking capacity Icu=36kA, 415V AC 4-pole; circuit breaker w/o Electronic Trip Unit N connected+measured without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT3 standard breaking capacity Icu=36kA, 415V AC 3-pole; circuit breaker with ETU line protection ETU LP, LI IR=315A, overload protection IRM=4 xIR, short-circuit protection without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LI In=125A rated current IR=100...125A overload prot. II=625...1250A, short-circuit protection N conductor unprotected without auxiliary release without auxiliary/alarm switch with front terminals
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=160A rated current IR=125...160A overload prot. II=800...1600A, short-circuit protection without auxiliary release without auxiliary/alarm switch with front terminals
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=20A rated current IR=16...20A overload protection II=200...300A, short-circuit protection without auxiliary release without auxiliary/alarm switch with front terminals
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=50A rated current IR=50A overload protection II=200A, short-circuit prot. without auxiliary release without auxiliary/alarm switch with front terminals
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=160A rated current IR=160A overload protection II=640A, short-circuit prot. without auxiliary release without auxiliary/alarm switch with front terminals
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=63A rated current IR=63A overload protection II=252A, short-circuit prot. without auxiliary release without auxiliary/alarm switch with front terminals
circuit breaker 3VT3 standard breaking capacity Icu=36kA, 415V AC 4-pole; circuit breaker w/o Electronic Trip Unit N connected without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT2 high breaking capacity Icu=65kA, 415V AC 3-pole; circuit breaker w/o Electronic Trip Unit without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT2 standard breaking capacity Icu=36kA, 415V AC 3-pole; circuit breaker with ETU 3-pole, line protection ETU LP, LI IR=200A, overload protection IRM=4 xIR, short-circuit protection, without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LI In=25A rated current IR=20...25A overload protection II=250...375A, short-circuit protection N conductor unprotected without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT3 high breaking capacity Icu=65kA, 415V AC 3-pole; circuit breaker with ETU motor/transformer protection ETU MP, LI IR=250...630A, overload protection IRM=0.5...6kA short-circuit protection, without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=16A rated current IR=12.5...16A overload prot. II=160...240A, short-circuit protection without auxiliary release without auxiliary/alarm switch with front terminals
circuit breaker 3VT3 high breaking capacity Icu=65kA, 415V AC 4-pole; circuit breaker w/o Electronic Trip Unit N connected without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=100A rated current IR=80...100A overload prot. II=500...1000A, short-circuit protection without auxiliary release without auxiliary/alarm switch with front terminals
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LI In=20A rated current IR=16...20A overload protection II=200...300A, short-circuit protection N-conductor unprotected without auxiliary release without auxiliary/alarm switch with front terminals
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=63A rated current IR=50...63A overload protection II=315...630A, short-circuit protection without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LI In=16A rated current IR=12.5...16A overload prot. II=160...240A, short-circuit protection N conductor unprotected without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LI In=32A rated current IR=25...32A overload protection II=160...320A, short-circuit protection N conductor unprotected without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, motor protection trip unit TM, LI In=63A rated current IR=50...63A overload protection II=630A, short-circuit prot. without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LIN In=125A rated current IR=125A overload protection II=500A, short-circuit prot. N conductor protected without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=80A rated current IR=80A overload protection II=320A, short-circuit prot. without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=20A rated current IR=16...20A overload protection II=200...300A, short-circuit protection without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=63A rated current IR=63A overload protection II=252A, short-circuit prot. without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LIN In=100A rated current IR=80...100A overload prot. II=500...1000A, short-circuit protection N conductor protected without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, motor protection trip unit TM, LI In=40A rated current IR=32...40A overload protection II=400A, short-circuit prot. without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LI In=100A rated current IR=100A overload protection II=400A, short-circuit prot. N conductor unprotected without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LI In=63A rated current IR=50...63A overload protection II=315...630A, short-circuit protection N conductor unprotected without auxiliary release without auxiliary/alarm switch
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LIN In=160A rated current IR=125...160A overload prot. II=800...1600A, short-circuit protection N conductor protected without auxiliary release without auxiliary/alarm switch