Siemens 3RT1326-1AH20 — Contactors

Siemens 3RT1326-1AH20 SIRIUS Power Contactor, S0 Frame, 4NO,

MPN3RT1326-1AH20

Siemens SIRIUS power contactor, S0 frame, 3RT1326-1AH20, 4 NO main contacts, 11 kW at 400 V AC-2, screw-type terminals, 61 x 85 x 91 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RT1326-1AH20 — Identification
ParameterValue
Contactor frame sizeS0
3RT1326-1AH20 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1326-1AH20 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz48 V
3RT1326-1AH20 — Contacts & Poles
ParameterValue
Main poles4
Main NO contacts4
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1326-1AH20 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 63 A
Short-circuit coordination type 2, fusefuse gL/gG: 35 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1326-1AH20 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1326-1AH20 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1326-1AH20 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1326-1AH20 — Mechanical
ParameterValue
Width61 mm
Height85 mm
Depth91 mm

Product details

Integrator note on the 3RT1326-1AH20

The Siemens SIRIUS 3RT1326-1AH20 is a size S0 power contactor with four normally-open main contacts, rated for 11 kW at 400 V in AC-2 duty — that's the motor switching figure for slip-ring or wound-rotor motors, where the contactor makes and breaks under load. The operating current at AC-12 (resistive) tops out at 10 A, so for general switching of heaters or transformers, that's the number to size against. The S0 frame takes 61 mm width on the rail, 85 mm height, 91 mm depth — leaves room for auxiliary blocks alongside without crowding the next device. The main contacts accept 2x (1... 2.5 mm²) solid or 2x (2.5... 6 mm²) stranded, max 2x 10 mm². Auxiliary terminals take 2x (0.5... 1.5 mm²) solid or 2x (0.75... 2.5 mm²), max 2x 4 mm². That covers most control wiring in a mill panel — spring-cage fans might need an adapter.

Environmental and installation constraints

Above that, you'd need to account for reduced air density on cooling and dielectric strength. Front face is IP20, terminals are IP00 — so the contactor itself is touch-safe on the front but the terminal area expects enclosure protection.

Short-circuit coordination

These numbers matter when designing a motor branch circuit for selectivity with upstream breakers.

Frequently asked questions

What are the key ratings for this contactor?

It is a size S0 power contactor with 4 normally-open main contacts. At 400 V in AC-2 duty (slip-ring motor switching), it is rated for 11 kW. The maximum operating current at AC-12 (resistive) is 10 A. Operating temperature range is -25 to +60 °C, and it mounts on 35 mm DIN rail.

What wire sizes does the 3RT1326-1AH20 accept?

Main circuit screw terminals accept 2x (1... 2.5 mm²) or 2x (2.5... 6 mm²) stranded, max 2x 10 mm². Auxiliary terminals accept 2x (0.5... 1.5 mm²) or 2x (0.75... 2.5 mm²) solid, max 2x 4 mm².

What are the physical dimensions of the 3RT1326-1AH20?

Width is 61 mm, height is 85 mm, and depth is 91 mm. It is an S0 frame size designed for screw or snap-on mounting onto 35 mm DIN rail per EN 50022.

What short-circuit protection is required for this contactor?

For type 2 coordination (no damage), use a gL/gG fuse rated 35 A upstream. For type 1 coordination (contactor may be damaged but no hazard), a 63 A gL/gG fuse is acceptable.

MPN
3RT1326-1AH20