Skip to main content
Siemens 3VM1140-3ED42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VM1140-3ED42-0AA0 MCCB, 40 A, 4-Pole, 76 kA

MPN3VM1140-3ED42-0AA0
Active

Siemens SENTRON 3VM1140-3ED42-0AA0, molded case circuit breaker, 4-pole, 40 A, TM210 release, 76 kA at 240 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VM1140-3ED42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VM1140-3ED42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C39 A
Current at 60 °C39 A
Current at 65 °C38 A
Current at 70 °C37 A
Switching capacity classN
Breaking capacity at 240 V76 kA
Breaking capacity at 415 V53 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V12 kA
Power loss, max.11 W
3VM1140-3ED42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VM1140-3ED42-0AA0 — Construction & Connection
ParameterValue
Main circuit connector arrangementFront connection
Protection class (IP), frontIP40
3VM1140-3ED42-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VM1140-3ED42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VM1140-3ED42-0AA0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.1 in
Width (in)4 in
Depth (in)2.8 in

Product details

SENTRON 3VM1140-3ED42-0AA0 — 40 A MCCB with TM210 release

The Siemens SENTRON 3VM1140-3ED42-0AA0 is a 4-pole molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current Iu of 40 A and a TM210 thermal-magnetic release with an adjustable short-circuit trip threshold up to 400 A. Breaking capacity is 76 kA at 240 V AC, 53 kA at 415 V, 32 kA at 440 V, and 12 kA at 500 V — so at typical 400 V distribution voltages it clears faults well above the 40 A frame rating, giving headroom for high-fault panels. The 70 mm depth × 101.6 mm width × 130 mm height footprint fits standard MCCB panel cutouts; front IP40 protection suits enclosed panel mounting where the breaker face is behind a door.

Rated current holds at 40 A from 40 °C through 50 °C, then steps down to 39 A at 55–60 °C, 38 A at 65 °C, and 37 A at 70 °C — so in a warm panel (55 °C ambient) you lose 1 A per pole, not enough to force a frame upsizing for most loads. Maximum power loss is 11 W.

MPN
3VM1140-3ED42-0AA0