Skip to main content
Siemens 3VM1140-5ED32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VM1140-5ED32-0AA0 SENTRON MCCB, 40 A, 3-Pole, 187 k

MPN3VM1140-5ED32-0AA0
Active

Siemens SENTRON 3VM1140-5ED32-0AA0, molded case circuit breaker, 3-pole, 40 A, TM210 thermal-magnetic release, 187 kA at 240 V AC, line protection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VM1140-5ED32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VM1140-5ED32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C39 A
Current at 60 °C39 A
Current at 65 °C38 A
Current at 70 °C37 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V76 kA
Breaking capacity at 500 V17 kA
Power loss, max.11 W
3VM1140-5ED32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VM1140-5ED32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront connection
Protection class (IP), frontIP40
3VM1140-5ED32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VM1140-5ED32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VM1140-5ED32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VM1140-5ED32-0AA0 is a 3-pole molded case circuit breaker rated 40 A continuous at 40 °C, with a TM210 thermal-magnetic overcurrent release. Just the breaker, the trip curve, and the interrupting capacity. Interrupting capacity is the headline here: 187 kA at 240 V AC, 121 kA at 415 V, 76 kA at 440 V, and 17 kA at 500 V. That's high-rupture-capacity territory — enough to handle large transformer-fed faults or tie into a high-fault utility feed without cascading upstream. Thermal derating is flat from 40 °C to 50 °C (40 A), then drops to 39 A at 55–60 °C, 38 A at 65 °C, and 37 A at 70 °C. If the panel runs hot, you lose 3 A off the top — plan the load margin accordingly.

Panel footprint is 76.2 mm wide, 130 mm tall, 70 mm deep — standard 3-pole MCCB slot on a DIN rail or direct-mount plate. Rated insulation voltage 800 V, max operating voltage 690 V AC, 500 V DC. Power loss is 11 W maximum.

MPN
3VM1140-5ED32-0AA0