Skip to main content
Siemens 5SN6450-7CN — 4-Pole MCB (DIN Rail)

Siemens 5SN6450-7CN SENTRON MCB, 4P, C-Curve, 50A, 6kA

MPN5SN6450-7CN

Siemens SENTRON miniature circuit breaker, 4-pole, C-curve, 50 A, 6 kA per EN 60898, 400 V AC, 4 MW units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SN6450-7CN — Identification
ParameterValue
Brand nameSENTRON
5SN6450-7CN — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated voltage, AC (multi-phase)440 V
5SN6450-7CN — Protection
ParameterValue
Tripping characteristic (trip curve)C
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
5SN6450-7CN — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SN6450-7CN — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)Periodically +55°C, max. 95% humidity
5SN6450-7CN — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)3.6 W

Product details

The Siemens 5SN6450-7CN is a SENTRON miniature circuit breaker (MCB) rated 50 A with a C tripping characteristic, 4 poles, and a 6 kA breaking capacity per EN 60898 at 400 V AC. Pollution degree 2 covers normal industrial environments with only non-conductive contamination that might become temporarily conductive due to condensation.

Sourcing and lifecycle — what to expect

The MCB is sealable, halogen-free, and silicon-free — relevant for installations in clean rooms, food processing, or areas with sensitive electronics where outgassing or corrosion from halogens or silicones is a concern.

Integration notes — panel fit and wiring

The 5SN6450-7CN accepts solid conductors up to 25 mm² at the terminals — enough for 50 A on a 4-pole breaker, but watch the torque spec in the datasheet. The power loss per pole at rated current in hot operating state is 3.6 W, so for a 4-pole unit you're looking at about 14.4 W total heat dissipation inside the enclosure. Factor that into your thermal budget, especially if the panel is sealed or has multiple MCBs in a row. If the panel sits in a hot, humid environment without climate control, the MCB will handle it, but the surrounding temperature influence may shift the thermal trip curve — derate if you're running near the 50 A limit at elevated ambient.

Frequently asked questions

What is the breaking capacity of the 5SN6450-7CN?

The breaking capacity is 6 kA according to EN 60898 at 400 V AC. This is the Icn rating — the maximum prospective short-circuit current the MCB can safely interrupt at its rated voltage.

Will the 5SN6450-7CN drop into a panel specified for the 5SL4363-7?

The 5SN6450-7CN is 72 mm wide (4 MW units) versus 54 mm (3 MW) for the 5SL4363-7, so it takes up one extra module width. Depth (76 mm) and height (90 mm) are identical, and both mount on DIN rail. If the panel has the spare width, it will fit mechanically, but the 5SN6450-7CN is a 4-pole unit while the 5SL4363-7 is 3-pole — you're adding the neutral pole.

Where can I buy the 5SN6450-7CN and how is it quoted?

The 5SN6450-7CN is sourced to order through independent distribution. Submit an RFQ for current pricing and lead time — availability and price are confirmed at quote time.

MPN