Siemens 5SY4540-7 — 1-Pole MCB (DIN Rail)

Siemens 5SY4540-7 SENTRON MCB, 40 A, C-Curve, 2-Pole, 10 kA

MPN5SY4540-7
Active

Siemens SENTRON 5SY4540-7 miniature circuit breaker, 40 A, C characteristic, 2-pole (1P+N), 10 kA per EN 60898, 15 kA per IEC 60947-2, 2 MW, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY4540-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityMechanical engineering / industry
5SY4540-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)10 kA
Energy limitation class3
Overvoltage categoryIII
5SY4540-7 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY4540-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

Integrator's spec recap

The Siemens SENTRON 5SY4540-7 is a 2-pole (1P+N) miniature circuit breaker rated 40 A at 35 °C with a C tripping characteristic. It snaps onto a DIN rail via the quick assembly system and occupies 2 modular width units (36 mm wide). The 10 kA breaking capacity per EN 60898 covers most residential and light commercial panelboards; the 15 kA rating per IEC 60947-2 gives headroom for industrial distribution where the prospective fault current is higher. The C-curve means the magnetic trip operates at 5 to 10 times In, so it handles moderate inrush from motor starters or transformers without nuisance tripping, but still clears a hard short fast enough for cable protection.

Thermal derating and ambient limits

The 40 A rating holds at 35 °C. At 45 °C the continuous current drops to 36.28 A; at 50 °C it is 34.96 A; at 55 °C it is 33.6 A; at 60 °C it is 32.16 A. If the panel internal ambient runs above 35 °C, size the upstream protection for the derated value, not the nameplate 40 A. The breaker operates from -40 °C to 75 °C ambient. Humidity must be managed: max 95% up to 55 °C, then derated to 55% at 70 °C and 35% at 75 °C. In a sealed enclosure with high moisture load, factor that into the ventilation design.

Mounting and integration

Mounts in any position on a DIN rail. The installation depth is 70 mm; overall depth is 76 mm. Combined terminals at top and bottom accept copper conductors. The IP20 rating applies with connected conductors — suitable for enclosed panelboards, not for wet-area standalone use. Pollution degree 3 and overvoltage category III mean the breaker is rated for fixed installations inside industrial enclosures where conductive pollution may occur, not just clean residential panels.

Frequently asked questions

Where can I buy 5SY4540-7 and how is it quoted?

The 5SY4540-7 is sourced and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time through our supply desk.

What are the key ratings of 5SY4540-7?

Rated 40 A at 35 °C, C tripping characteristic, 2-pole (1P+N), 10 kA breaking capacity per EN 60898 and 15 kA per IEC 60947-2. Occupies 2 modular width units (36 mm).

Does 5SY4540-7 have a DC breaking rating?

Yes, per IEC 60947-2 the DC breaking capacity is 15 kA.