Siemens 5SY6425-6 — 4-Pole MCB (DIN Rail)

Siemens 5SY6425-6 SENTRON MCB, 4P B-25A 6kA/15kA

MPN5SY6425-6
Active

Siemens SENTRON 5SY6 series, 4-pole miniature circuit breaker, 25 A B-curve, 6 kA (EN 60898) / 15 kA (IEC 60947-2), 400 V AC, quick assembly system, IP20.

$36.83Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY6425-6 — Identification
ParameterValue
Type / order code5SY6
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY6425-6 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC400 V
Rated current (In), AC25 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY6425-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Rated breaking capacity (Icn), per EN 608986 kA
Rated breaking capacity, per IEC 60947-215 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SY6425-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY6425-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY6425-6 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

25 A B-curve 4-pole MCB for panel protection

It's not the curve for motor starting (that's C or D), but for protecting a 4-wire distribution branch in a panel, this is the standard pick. That's enough headroom for a typical sub-distribution board fed from a 630 kVA transformer.

DIN-rail fit and wiring

Any mounting position is permitted, which simplifies layout in a crowded enclosure. Terminals accept solid or stranded conductors from 0.75 up to 35 mm² — that's a wide range, covering everything from 1.5 mm² control wiring up to 10 mm² feeder tails. Combined top and bottom terminals mean you can bus-bar the line side and still land the load side without extra adapters. IP20 with conductors connected — standard for enclosed panel gear.

Environmental tolerance

That covers most indoor panel environments, including unheated electrical rooms. Humidity tolerance is specified up to 95% at 55 °C, derating to 35% at 75 °C — fine for non-condensing conditions in temperate climates.

Frequently asked questions

What is the breaking capacity of 5SY6425-6?

Rated 6 kA per EN 60898 and 15 kA per IEC 60947-2. The 15 kA figure under the industrial standard is the practical limit for fault interruption in a panel.

What conductor sizes does 5SY6425-6 accept?

Solid or stranded conductors from 0.75 mm² up to 35 mm². Combined top and bottom terminals allow bus-bar connection on the line side.

Where can I buy 5SY6425-6?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Does 5SY6425-6 replace 5SY3132-6 in an existing panel?

No — 5SY3132-6 is a different pole count and current rating. The 5SY6425-6 is a 4-pole 25 A B-curve; verify the existing breaker's ratings before substituting. The DIN-rail footprint and terminal range are similar, but the electrical ratings must match the circuit design.

MPN
5SY6425-6