Skip to main content
Omron E3Z-T61-L DC12-24 — Photoelectric Sensors

Omron E3Z-T61-L DC12-24 Through-beam Photoelectric Sensor, 1

MPNE3Z-T61-L DC12-24

Omron E3Z-T61-L DC12-24, Through-beam Photoelectric Sensor, NPN Emitter, Infrared Light, 15 m, Pre-wired 2 m.

$259.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

E3Z-T61-L DC12-24 — Sensing
ParameterValue
Sensing methodThrough-beam
Sensing distance15 m
E3Z-T61-L DC12-24 — Other specifications
ParameterValue
NPN outputEmitter
Type of lightInfrared light
Connection methodPre-wired (2 m)

Product details

The E3Z-T61-L DC12-24: Output listed as 'NPN output Emitter' tells you this unit sends the beam, it does not switch a load. The emitter powers the infrared LED; the receiver pulls the NPN transistor low on detection. If your BOM calls for an E3Z-T61-L, you already know the receiver is separately ordered. The 15 m through-beam range is the maximum clean-air distance between emitter and receiver; factor in dust, steam, or misalignment and you'll derate. Pre-wired 2 m cable means you wire straight to the terminal block in the panel—no extra connector sourcing.

Compact photoelectric sensor with built-in amplifier. Same-day delivery available for 1 unit.

Frequently asked questions

What is the sensing distance of the Omron E3Z-T61-L DC12-24?

15 m through-beam maximum, as stated for this emitter sensor.

Is the E3Z-T61-L DC12-24 an NPN or PNP sensor and what is its output configuration?

NPN output, specifically an emitter (transmitter) that sends infrared light. It does not switch a load—the receiver does.

What is the difference between E3Z-T61 and E3Z-T61-L?

The -L suffix denotes the emitter unit. The standard E3Z-T61 is the receiver. They work as a pair.

What is the wiring and pinout for the E3Z-T61-L DC12-24?

Pre-wired 2 m cable—brown/blue for DC supply, plus the emitter output wire (typically black). Consult the Omron E3Z wiring diagram for exact color code.

Will E3Z-T61-L DC12-24 drop into a panel wired for a G7SA5A1B safety relay?

No—G7SA5A1B is a 6-pole safety relay, entirely different function and form factor. The E3Z-T61-L is a photoelectric sensor emitter, not a relay.

MPN
E3Z-T61-L DC12-24