Schneider Electric 18683
MPN18683
Active
RCCB with re-closer - RED - 2 poles - 40 A - class A - 30 mA
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Control type | Toggle |
| Network type | AC |
| Protection type | Recloser |
| Range of product | Acti9 |
| Product or component type | Residual current circuit breaker (RCCB) |
| Voltage | 500 V |
| [Ue] rated operational voltage | 230 V AC 50 Hz phase to neutral |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Surge current | 250 A |
| Current | 40 A |
| Rated conditional short-circuit current | Inc: 6 kA - associated with DPN, 40 A Inc: 6 kA - associated with DPNN, 40 A Inc: 10 kA - associated with iC60N, 25 A Inc: 10 kA - associated with iC60H, 25 A Inc: 10 kA - associated with iC60L, 25 A Inc: 6 kA - associated with iC60N, 40 A Inc: 6 kA - associated with iC60H, 40 A Inc: 6 kA - associated with iC60L, 40 A Inc: 10 kA - associated with NG125, 25 A Inc: 6 kA - associated with NG125, 40 A Inc: 10 kA - associated with gG fuse, 25 A Inc: 6 kA - associated with gG fuse, 40 A |
| [Im] rated making and breaking capacity | Idm 630 A 230 V |
All specifications
| Parameter | Value |
|---|---|
| Network frequency | 50 Hz |
| Poles description | 2P |
| IP degree of protection | IP20 |
| Mounting mode | Fixed |
| Mounting support | 35 mm symmetrical DIN rail |
| Wire stripping length | 12 mm |
| Connections - terminals | Guard tunnel terminal 35 mm² rigid Guard tunnel terminal 25 mm² flexible |
| Auxiliary connection terminal | Tunnel type terminal in 2.5 mm² flexible Tunnel type terminal in 2.5 mm² rigid |
| Pollution degree | 2 |
| Relative humidity | 95 % at 55 °C |
| Depth | 79.5 mm |
| Width | 71 mm |
| Height | 115 mm |
| Mechanical durability | 1000 cycles open-close |
| Standards | EN 61008 IEC 61008 |
| Reset | Fault reset earth leakage |
| 9 mm pitches | 8 |
| Test function | Manual at > 100 V |
| Operating mode | Reclosing time: 90 s Maximum operational frequency: 15/hour Max nb of consecutive restart: 3 Min interval between 2 closings: 180 s Insulation fault presence monitoring Stopping restart cycle if insulation fault present Restart in event of transient insulation fault |
| Earthing system | TN-S TT |
| Tropicalisation | 2 |
| Local signalling | 1 red LED Recloser : ON/OFF indication Residual current device : ON/OFF indication |
| Neutral position | Left |
| Device short name | RED |
| Tightening torque | 2 N.m |
| Device location in system | Outgoer |
| Earth-leakage sensitivity | 30 mA |
| Minimum leakage resistance | 70 kOhm at operating 20 kOhm at non-operating |
| Electromagnetic compatibility | 8/20 µs wave immunity, 250 A |
| Earth-leakage protection class | Type A |
| Ambient air temperature for storage | -20...60 °C |
| Earth-leakage protection time delay | Instantaneous |
| Ambient air temperature for operation | -5...40 °C |
MPN