18688 key specifications
ParameterValue
Control typeToggle
Network typeAC
Protection typeRecloser
Range of productActi9
Product or component typeResidual current circuit breaker (RCCB)
Signalling circuit voltageAC: 5...230 V DC: 5...230 V
Voltage500 V
[Ue] rated operational voltage230 V AC 50 Hz phase to neutral
[Uimp] rated impulse withstand voltage4 kV
Surge current250 A
Current25 A
Rated conditional short-circuit currentInc: 6 kA - associated with DPN, 40 A Inc: 10 kA - associated with DPNN, 40 A Inc: 10 kA - associated with iC60N, 25 A Inc: 10 kA - associated with iC60H, 25 A Inc: 10 kA - associated with iC60L, 25 A Inc: 10 kA - associated with NG125, 25 A Inc: 10 kA - associated with gG fuse, 25 A

All specifications

18688 additional specifications
ParameterValue
[Im] rated making and breaking capacityIdm 630 A 230 V
Network frequency50 Hz
Poles description2P
IP degree of protectionIP20
Mounting modeFixed
Mounting support35 mm symmetrical DIN rail
Wire stripping lengthPower circuit: 12 mm Signaling: 9 mm
Connections - terminalsGuard tunnel terminal 35 mm² rigid Guard tunnel terminal 35 mm² flexible Guard tunnel terminal 35 mm² flexible with ferrule
Auxiliary connection terminalTunnel type terminal in 2.5 mm² flexible Tunnel type terminal in 2.5 mm² rigid Tunnel type terminal in 2.5 mm² flexible with ferrule
Pollution degree2
Relative humidity95 % at 55 °C
Depth79.5 mm
Width71 mm
Height115 mm
Mechanical durability1000 cycles open-close
StandardsIEC 61008 EN 61008
ResetFault reset earth leakage
9 mm pitches8
Test functionManual at > 100 V
Operating modeReclosing time: < 90 s Max nb of consecutive restart: 3 Min interval between 2 closings: 180 s Stopping restart cycle if insulation fault present Insulation fault presence monitoring
Earthing systemTT TN-S
Tropicalisation2
Local signalling2 LEDs Residual current device : ON/OFF indication Recloser : ON/OFF indication
Neutral positionRight
Device short nameREDs
Tightening torquePower circuit: 2 N.m Signaling: 0.4 N.m
Device location in systemOutgoer
Earth-leakage sensitivity300 mA
Minimum leakage resistance5 kOhm at operating 2.5 kOhm at non-operating
Signal contacts composition1NO or 1NC or intermittent 1 Hz
Electromagnetic compatibility8/20 µs wave immunity, 250 A
Earth-leakage protection classType A
Ambient air temperature for storage-20...60 °C
Earth-leakage protection time delayInstantaneous
Ambient air temperature for operation-5...40 °C