Skip to main content
Schneider Electric 18691

Schneider Electric 18691

MPN18691
Obsolete

RCCB with re-closer - RED - 2 poles - 60 A - class A - 30 mA

$320.80Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

18691 key specifications
ParameterValue
Control typeToggle
Network typeAC
Protection typeRecloser
Range of productActi9
Product or component typeResidual current circuit breaker (RCCB)
Signalling circuit voltageAC: 5...230 V DC: 5...230 V
Voltage500 V
[Ue] rated operational voltage230 V AC 50 Hz phase to neutral
[Uimp] rated impulse withstand voltage4 kV
Surge current250 A
Current63 A
Rated conditional short-circuit currentInc: 10 kA - associated with C120L, 63 A Inc: 10 kA - associated with iC60N, 63 A Inc: 10 kA - associated with NG125, 63 A Inc: 15 kA - associated with gG fuse, 40 A Inc: 15 kA - associated with iC60L, 40 A Inc: 10 kA - associated with iC60L, 63 A Inc: 15 kA - associated with NG125, 40 A Inc: 10 kA - associated with iC60H, 63 A Inc: 10 kA - associated with gG fuse, 63 A Inc: 25 kA - associated with gG fuse, 25 A Inc: 10 kA - associated with C120N, 63 A Inc: 10 kA - associated with C120H, 63 A Inc: 15 kA - associated with iC60H, 40 A

All specifications

18691 additional specifications
ParameterValue
[Im] rated making and breaking capacityIdm 630 A 230 V
Network frequency50 Hz
Poles description2P
IP degree of protectionIP20
Mounting modeFixed
Mounting support35 mm symmetrical DIN rail
Wire stripping lengthPower circuit: 12 mm Signaling: 9 mm
Connections - terminalsGuard tunnel terminal 35 mm² rigid Guard tunnel terminal 35 mm² flexible Guard tunnel terminal 35 mm² flexible with ferrule
Auxiliary connection terminalTunnel type terminal in 2.5 mm² flexible Tunnel type terminal in 2.5 mm² rigid Tunnel type terminal in 2.5 mm² flexible with ferrule
Pollution degree2
Relative humidity95 % at 55 °C
Depth79.5 mm
Width71 mm
Height115 mm
Mechanical durability1000 cycles open-close
StandardsEN 61008 IEC 61008
ResetFault reset earth leakage
9 mm pitches8
Test functionManual at > 100 V
Operating modeReclosing time: < 90 s Max nb of consecutive restart: 3 Min interval between 2 closings: 180 s Stopping restart cycle if insulation fault present Insulation fault presence monitoring
Earthing systemTN-S TT
Tropicalisation2
Local signalling2 LEDs Residual current device : ON/OFF indication Recloser : ON/OFF indication
Neutral positionLeft
Device short nameREDs
Tightening torquePower circuit: 2 N.m Signaling: 0.4 N.m
Device location in systemOutgoer
Earth-leakage sensitivity30 mA
Minimum leakage resistance16 kOhm at operating 8 kOhm at non-operating
Signal contacts composition1NO or 1NC or intermittent 1 Hz
Electromagnetic compatibility8/20 µs wave immunity, 250 A
Earth-leakage protection classType A
Ambient air temperature for storage-20...60 °C
Earth-leakage protection time delayInstantaneous
Ambient air temperature for operation-5...40 °C
MPN
18691