Skip to main content
Schneider Electric 18721

Schneider Electric 18721

MPN18721
Obsolete

Miniature circuit breaker (MCB), Acti9 NG125H, 2P, 63A, C curve, 36kA (IEC/EN 60947-2)

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

18721 key specifications
ParameterValue
Control typeManual tripping test Toggle
Network typeDC AC
Product or component typeMiniature circuit-breaker
Voltage690 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ue] rated operational voltage380...415 V AC 50/60 Hz 500 V AC 50/60 Hz 220...240 V AC 50/60 Hz 440 V AC 50/60 Hz <= 250 V DC
[Uimp] rated impulse withstand voltage8 kV conforming to EN/IEC 60947-2
Breaking capacity12 kA Icu at 500 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at <= 250 V DC conforming to EN/IEC 60947-2
Current63 A at 40 °C
[Ics] rated service breaking capacity52.5 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 27 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 22.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 9 kA 75 % conforming to EN/IEC 60947-2 - 500 V AC 50/60 Hz 25 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
Network frequency50/60 Hz
Poles description2P
Number of protected poles2

All specifications

18721 additional specifications
ParameterValue
Utilisation categoryCategory A conforming to IEC 60947-2
IK degree of protectionIK05 conforming to EN/IEC 62262
IP degree of protectionIP20 conforming to IEC 60529
Mounting modeClip-on
Mounting support35 mm symmetrical DIN rail
Mounting positionVertical
Wire stripping length20 mm
Connections - terminalsTunnel type terminals1.5...50 mm² rigid Tunnel type terminals1...35 mm² flexible
Pollution degree3 conforming to IEC 60947-2
Relative humidity95 % at 55 °C
Depth81 mm
Width54 mm
Height103 mm
Electrical durability10000 cycles
Mechanical durability20000 cycles
StandardsEN/IEC 60947-2
RangeActi9
Curve codeC
9 mm pitches6
Tropicalisation2 conforming to IEC 60068-1
Local signallingON/OFF indication Trip indicator
Device short nameNG125H
Tightening torque3.5 N.m
Device applicationDistribution
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Magnetic tripping limit8 x In +/- 20 %
Earth-leakage protectionSeparate block
Provision for padlockingPadlockable
Suitability for isolationYes conforming to IEC 60947-2
Contact position indicatorYes
Locking options descriptionIntegrated padlocking
Ambient air temperature for storage-40...70 °C
Ambient air temperature for operation-30...70 °C
Comb busbar and distribution block compatibilityYES
MPN
18721