Schneider Electric 24857
MPN24857
Obsolete
Breaker, DIN Rail Mount, 50A, 2P, C Curve, 440VAC|Breaker, DIN Rail Mount, 50 Amp, 2-Pole, C Curve, 440 Volt AC
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Control type | Toggle |
| Network type | AC DC |
| Range of product | C60 |
| Product or component type | Miniature circuit-breaker |
| Voltage | 500 V |
| [Ue] rated operational voltage | 440 V AC 50/60 Hz 230...240 V AC 50/60 Hz 400...415 V AC 50/60 Hz 230/400 V AC 50/60 Hz |
| Breaking capacity | 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 A Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 25 kA Icu at 125 V DC 2P conforming to EN/IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to EN/IEC 60947-2 50 kA Icu at <= 250 V DC 4P conforming to EN/IEC 60947-2 |
| Current | 50 A at 30 °C |
| [Ics] rated service breaking capacity | 7.5 kA conforming to EN/IEC 60947-2 - 400...415 V AC 50/60 Hz 7500 A conforming to EN 60898 - 230/400 V AC 50/60 Hz 15 kA conforming to EN/IEC 60947-2 - 230...240 V AC 50/60 Hz 5 kA conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz |
| Network frequency | 50/60 Hz |
| Poles description | 2P |
| Number of protected poles | 2 |
All specifications
| Parameter | Value |
|---|---|
| IP degree of protection | IP20 conforming to IEC 60529 |
| Mounting mode | Clip-on |
| Mounting support | 35 mm symmetrical DIN rail |
| Connections - terminals | Tunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 2000 m |
| Depth | 73 mm |
| Width | 36 mm |
| Height | 81 mm |
| Mechanical durability | 20000 cycles |
| Standards | EN/IEC 60947-2 EN 60898 |
| Range | Multi9 |
| Curve code | C |
| 9 mm pitches | 4 |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Limitation class | 3 conforming to EN/IEC 60947-2 |
| Local signalling | ON/OFF indication |
| Device short name | C60H |
| Tightening torque | Power circuit: 3.5 N.m upside 3.5 N.m downside |
| Device application | Distribution |
| Overvoltage category | IV |
| Trip unit technology | Thermal-magnetic |
| Magnetic tripping limit | 5...10 x In |
| Earth-leakage protection | Separate block |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Contact position indicator | Yes |
| Ambient air temperature for storage | -40...70 °C |
| Ambient air temperature for operation | -25...60 °C |
| Comb busbar and distribution block compatibility | NO |
MPN