Schneider Electric 28566
MPN28566
Active
Monitoring relay Vigirex RM12T - 30 mA..30 A - 220..240 V AC
$268.74 – $521.27Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Type of measurement | Earth fault current internal measurement, range: 80...100 %, accuracy: +/- 10 % |
| Product or component type | Multiplexer |
| Supply voltage | 220...240 V AC 50/60 Hz 70...110 % |
| Current sensors compatibility | VigiPacT RMH monitoring relay |
| [Ithe] conventional enclosed thermal current | 8 A |
| Power consumption in | 8 VA |
| IK degree of protection | IK07 conforming to EN 50102 |
| IP degree of protection | IP40 on front face: conforming to EN/IEC 60529 IP30 on side parts: conforming to EN/IEC 60529 IP20 on connection terminals: conforming to EN/IEC 60529 |
| Communication service | Supervision via internal bus |
| Mounting support | DIN rail |
| Wire stripping length | Auxiliary power supply: 6 mm for bottom connection Earth leakage monitor: 6 mm for bottom connection Sensor: 6 mm for bottom connection Sensor: 6 mm for top connection |
| Connections - terminals | Auxiliary power supply: screw terminal cable(s) 0.2...2.5 mm² flexible AWG 22...AWG 12 Auxiliary power supply: screw terminal cable(s) 0.2...2.5 mm² rigid AWG 22...AWG 12 Auxiliary power supply: screw terminal cable(s) 0.25...2.5 mm² flexible with ferrule AWG 22...AWG 12 Earth leakage monitor: screw terminal cable(s) 0.2...2.5 mm² flexible AWG 22...AWG 12 Earth leakage monitor: screw terminal cable(s) 0.2...2.5 mm² rigid AWG 22...AWG 12 Earth leakage monitor: screw terminal cable(s) 0.25...2.5 mm² flexible with ferrule AWG 22...AWG 12 Sensor: screw terminal cable(s) 0.2...2.5 mm² flexible AWG 22...AWG 12 Sensor: screw terminal cable(s) 0.2...2.5 mm² rigid AWG 22...AWG 12 Sensor: screw terminal cable(s) 0.25...2.5 mm² flexible with ferrule AWG 22...AWG 12 |
All specifications
| Parameter | Value |
|---|---|
| Pollution degree | 3 conforming to IEC 60664-1 |
| Relative humidity | 95 % at 55 °C |
| Depth | 73.5 mm |
| Width | 106 mm |
| Height | 81 mm |
| Standards | EN/IEC 60947-2 Annex M EN/IEC 60755 |
| Range | VigiPacT |
| Monitoring | Electronics (continuous) Power supply (continuous) Relay/sensor link (continuous) Sensor/multiplexer RM12T and RM12T/RMH link (continuous) |
| 9 mm pitches | 12 |
| Minimum load | 10 mA at 12 V |
| Test function | Local |
| Device short name | RM12T |
| Relay application | Monitoring relay |
| Tightening torque | Auxiliary power supply: 0.5 N.m bottom Earth leakage monitor: 0.5 N.m bottom Sensor: 0.5 N.m bottom Sensor: 0.5 N.m top |
| Overvoltage category | IV |
| Mechanical robustness | Fire resistance conforming to IEC 60695-2-1 IK protection 2 joules: IK07 conforming to EN 50102 Vibrations 13.2...100 Hz: 0.7 g Vibrations 2...13.2 Hz: +/- 1 mm |
| Signal contacts composition | 1 NO |
| Electromagnetic compatibility | Conducted and radiated emissions: , B, conforming to CISPR 11 Conducted radio-frequency immunity test: , 3, conforming to IEC 61000-4-6 Electrostatic discharge immunity test: , 4, conforming to IEC 61000-4-2 High-energy conducted susceptibility: , 4, conforming to IEC 61000-4-5 Low-energy conducted susceptibility: , 4, conforming to IEC 61000-4-4 Radiated susceptibility: , 3, conforming to IEC 61000-4-3 |
| Ambient air temperature for storage | -40...85 °C |
| Ambient air temperature for operation | -25...55 °C |
MPN
28566