Schneider Electric 29472
MPN29472
Active
remote control source changeover. Transferpact. ACP plate and UA controller. 220 VAC to 240 VAC 50/60 Hz
$967.74 – $1,443.01Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Input type | Contacts customer voluntary order to transfer to source R |
| Output signal | Contacts customer: indication of operation in automatic or stop mode |
| Range of product | NSX100...250 Compact NS100...630 MasterPact NW MasterPact NT NSX400...630 Compact NS630b...1600 |
| Product or component type | Interface and control unit |
| Supply voltage | 220...240 V AC at 50/60 Hz |
| [Ie] rated operational current | AC-12: 4 A AC 440 V AC-12: 5 A AC 380/415 V AC-12: 8 A AC 110 V AC-12: 8 A AC 220/240 V AC-12: 8 A AC 24 V AC-12: 8 A AC 48 V AC-13: 6 A AC 110 V AC-13: 6 A AC 220/240 V AC-13: 7 A AC 24 V AC-13: 7 A AC 48 V AC-14: 4 A AC 110 V AC-14: 4 A AC 220/240 V AC-14: 5 A AC 24 V AC-14: 5 A AC 48 V AC-15: 3 A AC 220/240 V AC-15: 4 A AC 110 V AC-15: 5 A AC 24 V AC-15: 5 A AC 48 V DC-12: 0.4 A DC 250 V DC-12: 0.6 A DC 110 V DC-12: 2 A DC 48 V DC-12: 8 A DC 24 V DC-13: 2 A AC 24 V |
| [Ith] conventional free air thermal current | 8 A |
| IK degree of protection | Front: IK07 conforming to EN 50102 |
| IP degree of protection | IP20 connectors: conforming to EN 60529 IP40 front: conforming to EN 60529 IP30 side: conforming to EN 60529 |
| Standards | IEC 947-5-1 |
| Test function | By pressing the test button on the front of the controller |
| Operating mode | Automatic operation Forced operation on normal source Stop (both normal and replacement source off) Forced operation on replacement source |
| Selection modes | Circuit breaker on R Circuit breaker on N |
| Local signalling | On Off Fault trip |
| Device short name | ACP + UA |
| Interlocked device | MasterPact NT NSX400...630 MasterPact NW NSX100...250 Compact NS100...630 Compact NS630b...1600 |
| Complementary function | Voluntary transfer to replacement source (e.g. energy management commands) Forced normal source if replacement source not operational during peak-tariff Selection of type of normal source (single-phase or three-phase) Setting of maximum startup time for the replacement source Additional contact: transfer to replacement source only if contact is closed |
| Accessory (separate part category) | Interlocking accessory |
MPN