Schneider Electric 29584
MPN29584
Active
circuit breaker Compact NS100N - TMD - 25 A - 1 pole 1d
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Control type | Toggle |
| Network type | DC AC |
| Protection type | Short-circuit protection (magnetic) Overload protection (thermal) |
| Range of product | Compact NS100...630 |
| Product or component type | Circuit breaker |
| Long time pick-up adjustment type ir | Fixed |
| Instantaneous pick-up adjustment type ii | Fixed |
| Voltage | 750 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ue] rated operational voltage | 250 V DC conforming to IEC 60947-2 277 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947-2 |
| Breaking capacity | 25 kA at 240 V AC 50/60 Hz conforming to NEMA AB1 HIC 25 kA at 277 V AC 50/60 Hz conforming to NEMA AB1 HIC 25 kA Icu at 220 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 277 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 250 V DC 1P conforming to IEC 60947-2 50 kA Icu at 48/125 V DC 1P conforming to IEC 60947-2 |
| Current | 100 A at 40 °C 100 A at 65 °C |
All specifications
| Parameter | Value |
|---|---|
| Breaking capacity code | N |
| Magnetic tripping current | 190 A 640 A 1000 A 260 A 300 A 1250 A 500 A 800 A |
| [Ics] rated service breaking capacity | 25 kA at 220 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 277 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 250 V DC conforming to IEC 60947-2 50 kA at 48/125 V DC conforming to IEC 60947-2 |
| Network frequency | 50/60 Hz |
| Poles description | 1P |
| Protected poles description | 1t |
| Utilisation category | Category A |
| IK degree of protection | IK07 conforming to EN 50102 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| Mounting mode | Fixed |
| Mounting support | Backplate |
| Connection pitch | 35 mm |
| Upside connection | Front |
| Downside connection | Front |
| Pollution degree | 3 conforming to IEC 60947 |
| Depth | 86 mm |
| Width | 35 mm |
| Height | 161 mm |
| Electrical durability | 10000 cycles 277 V AC 50/60 Hz In conforming to IEC 60947-2 20000 cycles 277 V AC 50/60 Hz In/2 conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles |
| Standards | IEC 60947-2 |
| Trip unit name | TM-D |
| Local signalling | Positive contact indication |
| Trip unit rating | 25 A at 40 °C |
| Device short name | Compact NS100N |
| Device application | Distribution |
| Circuit breaker name | Compact NS100N |
| Trip unit technology | Thermal-magnetic |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Long time pick-up adjustment range | 0.8...1 x In |
| Ambient air temperature for storage | -50...85 °C |
| Ambient air temperature for operation | -25...70 °C |
| Instantaneous pick-up adjustment range | 300 A |
MPN