Skip to main content
Schneider Electric 47218

Schneider Electric 47218

MPN47218
Active

Circuit breaker frame, MasterPact NT08H2, 800A, 50kA/440VAC 50/60Hz (Icu), 4 poles, drawout, without control unit

$3,540.63Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

47218 key specifications
ParameterValue
Control typePush-button
Performance typeH2 50 kA 440 V AC
Product or component typeCircuit breaker
Voltage1000 V AC 50/60 Hz
[Ue] rated operational voltage690 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage12 kV
[Icw] rated short-time withstand current42 kA 0.5 s 42 kA 1 s 20 kA 3 s
Current800 A at 40 °C
[Ics] rated service breaking capacity42 kA at 220/415 V AC 50/60 Hz 42 kA at 440 V AC 50/60 Hz 50 kA at 525 V AC 50/60 Hz 50 kA at 690 V AC 50/60 Hz
[Icm] rated short-circuit making capacity105 kA 220/415 V AC at 50/60 Hz 105 kA 440 V AC at 50/60 Hz 88 kA 525 V AC at 50/60 Hz 88 kA 690 V AC at 50/60 Hz
[Icu] rated ultimate short-circuit breaking capacity50 kA at 220/415 V AC 50/60 Hz 50 kA at 440 V AC 50/60 Hz 42 kA at 525 V AC 50/60 Hz 42 kA at 690 V AC 50/60 Hz
Power dissipation in90 W

All specifications

47218 additional specifications
ParameterValue
Poles description4P
IP degree of protectionIP30 conforming to IEC 60529
Mounting modeDrawout
Mounting supportBackplate Rails
Connection pitch70 mm
Upside connectionFront Rear
Downside connectionFront Rear
Maximum closing response time50 ms
Pollution degree3 conforming to IEC 60664-1
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
Depth277 mm
Width358 mm
Height322 mm
Product weight39 kg
Electrical durability6000 cycles 440 V AC 50/60 Hz without maintenance conforming to EN/IEC 60947-2 3000 cycles 690 V AC 50/60 Hz without maintenance conforming to EN/IEC 60947-2 AC-23A: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to EN/IEC 60947-3 AC-23A: 3000 cycles 690 V AC 50/60 Hz without maintenance conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to EN/IEC 60947-3
Mechanical durability12500 cycles without maintenance
StandardsEN/IEC 60947-1 EN/IEC 60947-2
RangeMasterPacT
Control unitWithout control unit
Sensor rating400 A 800 A
Neutral positionLeft
Device applicationPower distribution protection
Circuit breaker nameMasterPact NT08H2
Selectivity categoryCategory B
Maximum breaking time25 ms
Suitability for isolationYes conforming to EN/IEC 60947-2
Ambient air temperature for storage-40...85 °C
Ambient air temperature for operation-25...70 °C
Integrated instantaneous protection (DIN in kA peak)81...99 kA
MPN
47218