| Parameter | Value |
|---|---|
| Type of setting | Selector |
| Type of measurement | Earth fault current internal measurement 80...100 % |
| Product or component type | Residual current protection relay |
| Residual earth-leakage sensitity adjustment type | Adjustable 9 settings |
| Supply voltage | 12...24 V AC 50/60 Hz 55...120 % 12...48 V DC 55...120 % |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Current sensors compatibility | VigiPacT TOA earth leakage current sensor VigiPacT A earth leakage current sensor VigiPacT L earth leakage current sensor |
| [Ithe] conventional enclosed thermal current | 8 A |
| Power consumption in | 4 VA |
| IK degree of protection | IK07 conforming to EN 50102 |
| IP degree of protection | IP40 on front face: conforming to EN/IEC 60529 IP30 on side parts: conforming to EN/IEC 60529 IP20 on connection terminals: conforming to EN/IEC 60529 |
| Mounting support | DIN rail |
All specifications
| Parameter | Value |
|---|---|
| Wire stripping length | Auxiliary power supply: 0.3 in (7 mm) for top connection Fault: 0.3 in (8 mm) for bottom connection Relay test and fault reset: 0.2 in (5 mm) for bottom connection Sensor: 0.2 in (5 mm) for top connection Voltage presence: 0.3 in (8 mm) for bottom connection |
| Connections - terminals | Auxiliary power supply terminal block 0.0003...0.004 in² (0.2...2.5 mm²) flexible AWG 24...AWG 12 Auxiliary power supply terminal block 0.0003...0.004 in² (0.2...2.5 mm²) rigid AWG 24...AWG 12 Auxiliary power supply terminal block 0.0004...0.004 in² (0.25...2.5 mm²) flexible AWG 24...AWG 12 Fault screw terminal 0.0003...0.004 in² (0.2...2.5 mm²) flexible AWG 24...AWG 12 Fault screw terminal 0.0003...0.006 in² (0.2...4 mm²) rigid AWG 24...AWG 12 Fault screw terminal 0.0004...0.004 in² (0.25...2.5 mm²) flexible AWG 24...AWG 12 Relay test and fault reset screw terminal 0.0002...0.002 in² (0.14...1 mm²) flexible AWG 26...AWG 16 Relay test and fault reset screw terminal 0.0002...0.002 in² (0.14...1.5 mm²) rigid AWG 26...AWG 16 Relay test and fault reset screw terminal 0.0004...0.0008 in² (0.25...0.5 mm²) flexible AWG 26...AWG 16 Sensor screw terminal 0.0002...0.002 in² (0.14...1 mm²) flexible AWG 26...AWG 16 Sensor screw terminal 0.0002...0.002 in² (0.14...1.5 mm²) rigid AWG 26...AWG 16 Sensor screw terminal 0.0004...0.0008 in² (0.25...0.5 mm²) flexible AWG 26...AWG 16 Voltage presence screw terminal 0.0003...0.004 in² (0.2...2.5 mm²) flexible AWG 24...AWG 12 Voltage presence screw terminal 0.0003...0.006 in² (0.2...4 mm²) rigid AWG 24...AWG 12 Voltage presence screw terminal 0.0004...0.004 in² (0.25...2.5 mm²) flexible AWG 24...AWG 12 |
| Pollution degree | 3 IEC 60664-1 |
| Relative humidity | 95 % 131 °F (55 °C) |
| Electrical shock protection class | Class II |
| Depth | 2.9 in (74 mm) |
| Width | 2.1 in (54 mm) |
| Height | 3.2 in (81 mm) |
| Standards | EN/IEC 60947-2 Annex M EN/IEC 60755 UL 1053 CAN/CSA C22.2 No. 144 |
| Range | VigiPacT |
| Reset | Manual reset |
| Category | 00992-UL VIGIREX GROUND FAULT RELAY & SENSOR |
| Monitoring | Electronics continuous) Power supply continuous) Relay/sensor link continuous) |
| 9 mm pitches | 6 |
| Minimum load | 10 mA 12 V |
| Test function | Remote test Local |
| Earthing system | TN-S IT TT |
| Device short name | RH99M |
| Relay application | Protection relay |
| Tightening torque | Auxiliary power supply: 5.3 lbf.in (0.6 N.m) top Fault: 5.3 lbf.in (0.6 N.m) bottom Relay test and fault reset: 2.21 lbf.in (0.25 N.m) bottom Sensor: 2.21 lbf.in (0.25 N.m) top Voltage presence: 5.3 lbf.in (0.6 N.m) bottom |
| Overvoltage category | IV |
| Mechanical robustness | Fire resistance IEC 60695-2-1 IK protection 2 joulesIK07 EN 50102 Vibrations 13.2...100 Hz0.7 g Vibrations 2...13.2 Hz+/- 1 mm |
| Tamperproof of settings | Protected by sealable cover |
| Earth-leakage time delay | Instantaneous for 0.03 A Adjustable 9 settings 0...4.5 s for 0.03...30 A |
| Earth-leakage sensitivity | 0.03...30 A |
| Electromagnetic compatibility | Conducted and radiated emissionsB CISPR 11 Conducted radio-frequency immunity test3 IEC 61000-4-6 Electrostatic discharge immunity test4 IEC 61000-4-2 High-energy conducted susceptibility4 IEC 61000-4-5 Low-energy conducted susceptibility4 IEC 61000-4-4 Radiated susceptibility3 IEC 61000-4-3 |
| Monitored distribution system | 1000 V - AC 50/60 Hz maximum) 1000 V - AC 400 Hz maximum) |
| Earth-leakage protection class | Type A |
| Ambient air temperature for storage | -67...185 °F (-55...85 °C) |
| Ambient air temperature for operation | -31...158 °F (-35...70 °C) |