Specifications

822TD10HUNI key specifications
ParameterValue
Series820
Voltage_in10 V
Voltage max240 V
Voltage withstand4 kV 1.2/50 µs IEC 60664-1
Current min100 mA 5 V
Current out15 A
Poles2
Enclosure_materialAgNi
MountingDIN Rail
Humidity max95
Depth63.5
Width17.78

All specifications

822TD10HUNI additional specifications
ParameterValue
Height88.9
Electrical life cycles30000 cycles
Mechanical life cycles15000000 cycles
StandardsIEC 61812-1
Awg_gaugeAWG 14
IP ratingIP20 IEC 60529 terminals) IP40 IEC 60529 front panel)
Torque3.5 lbf.in (0.4 N.m)
Dielectric4000 V between input and output 1000 V between open contacts
Accuracy-0.2
Control_typeWith adjustment knob front
Package_typePCE
Product typeTiming Relay
Product rangeLegacy
Reset time150 ms maximum
Current15
Switch_functionDPDT
Time_delay_typeMultifunction
Local signalling1 LED red 1 LED green
Supply voltage12
Time_delay_range100 ms...1 s 1...10 s 0.1...1 min 1...10 min 0.1...1 h 1...10 h 72 min...12 h 1...10 d
Temperature drift0.01 %/°C
Voltage240
Breaking cap icu4000 VA AC-1
Power consumption2.5 VA 240 V
Switching current15
Storage temperature-22...158 °F (-30...70 °C)
Electromagnetic compatibilityElectrostatic discharge 4 kV level 2 conforming to IEC 61000-4-2 Electrostatic discharge 8 kV level 2 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test 10 V/m level 3 conforming to IEC 61000-4-3 Surge immunity test 2 kV level 3 conforming to IEC 61000-4-5 Surge immunity test 1 kV level 3 conforming to IEC 61000-4-5 Fast transient bursts 2 kV level 3 conforming to IEC 61000-4-4 Conducted RF disturbances 10 V, 0.15...80 MHz level 3 conforming to IEC 61000-4-6 Immunity to microbreaks and voltage drops 30 %, 500 ms conforming to IEC 61000-4-11 Immunity to microbreaks and voltage drops 100 %, 20 ms conforming to IEC 61000-4-11
Main_product_or_component_typeTime delay relay
Operating temperature-4
Ordering and shipping details (Category)US10CP221127
MPN
822TD10HUNI