Skip to main content
Schneider Electric A9D07216 — Residual Current Breakers (RCCB/RCBO)

A9D07216 Acti9 iC60 RCBO, 16 A, 30 mA, C-curve, 2P

MPNA9D07216
Active

Schneider Electric Acti9 iC60 RCBO, A9D07216, 2P, 16 A rated current, 30 mA earth-leakage sensitivity, C-curve, 10 kA breaking capacity, clip-on DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D07216 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON, OFF, fault trip
A9D07216 — Electrical Ratings
ParameterValue
Rated current (In)16 A
Rated operational voltage (Ue)220...240 V AC 50 Hz
Poles description2P
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability10000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D07216 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60 RCBO
A9D07216 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible Tunnel type terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length12 mm for top or bottom connection
Terminal tightening torque2 N.m
Width36 mm
Height86 mm
Depth78 mm
A9D07216 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
IP degree of protectionIP40 (distribution enclosure) conforming to IEC 60529 IP20 conforming to IEC 60529
Relative humidity95 % at 55 °C
Tropicalisation2
A9D07216 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 61009-2-1

Product details

The Schneider Electric A9D07216 is an Acti9 iC60 RCBO — a combined residual-current circuit breaker with overcurrent protection, in a 2-pole, 16 A, C-curve configuration with 30 mA earth-leakage sensitivity. It integrates thermal-magnetic overcurrent trip and earth-leakage detection in a single 36 mm wide unit that clips onto a DIN rail, saving panel space over separate MCB and RCCD devices. The C-curve (magnetic trip 5...10 x In) suits it for inductive loads like small motors, pumps, and lighting where inrush currents are moderate.

Rated breaking capacity Icn is 10 kA at 220...240 V AC, 50 Hz per EN/IEC 61009-2-1, with an ultimate breaking capacity Icu of 15 kA at the same voltage per EN/IEC 60947-2. That extra Icu headroom means the device can interrupt a higher fault current once without needing replacement, useful in installations with upstream transformers or high prospective fault levels. For selectivity coordination with an upstream device, the 15 kA Icu gives you a wider window to achieve full discrimination.

Mounting and wiring in the panel

Tunnel terminals accept 1...35 mm² rigid or 1...25 mm² flexible cable; strip length 12 mm, tighten to 2 N·m. The 9 mm pole pitch matches standard Acti9 busbar systems for daisy-chaining outgoing circuits on the same phase. IP20 rated for finger-safe wiring; IP40 when enclosed in a distribution board. Local signalling shows ON, OFF, and fault-trip status through the toggle position — useful for fast fault isolation on a crowded rail.

Frequently asked questions

What is the breaking capacity of A9D07216?

The A9D07216 has a rated breaking capacity Icn of 10 kA at 220...240 V AC per EN/IEC 61009-2-1, and an ultimate breaking capacity Icu of 15 kA at the same voltage per EN/IEC 60947-2.

What does the C-curve on this RCBO mean?

The C-curve means the magnetic trip operates at 5...10 times the rated current (In), so for this 16 A unit, instantaneous trip occurs between 80 A and 160 A. This suits inductive loads like small motors and fluorescent lighting with moderate inrush.

Where can I buy A9D07216 and how is it quoted?

The A9D07216 is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time, no stock count or price is published here.

MPN