Skip to main content
Schneider Electric A9D16806 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D16806 IKQE RCBO, 6A C-Curve 10mA 10kA

MPNA9D16806
Obsolete

Schneider Electric Acti9 IKQE RCBO, 1P+N, 6 A, C-curve, 10 mA earth leakage, 10 kA breaking capacity, clip-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9D16806 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)10 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9D16806 — Electrical Ratings
ParameterValue
Rated current (In)6 A at 50 °C
Rated operational voltage (Ue)230 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D16806 — Identification
ParameterValue
Product nameIKQE RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
A9D16806 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules2
Terminal connectionsTunnel type terminal (top or bottom) 1...16 mm² rigid without cable end Tunnel type terminal (top or bottom) 1...10 mm² flexible without cable end Tunnel type terminal (top or bottom) 1...10 mm² flexible with cable end
Wire stripping lengthPower circuit: 13 mm for top or bottom connection
Terminal tightening torquePower circuit: 2 N.m top or bottom
Width18 mm
Height118 mm
Depth82 mm
A9D16806 — Environmental
ParameterValue
Operating ambient temperature-15...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2
A9D16806 — Approvals
ParameterValue
StandardsBS EN 61009-1

Product details

It protects a 1P+N final subcircuit against both overload/short-circuit (thermal-magnetic trip) and earth leakage, with a 10 mA sensitivity that catches even low-level leakage currents before they become a shock hazard or fire risk. Rated 6 A at 50 °C with a C-curve trip characteristic, it handles moderate inrush loads like small motors or lighting banks without nuisance tripping, while the 10 kA Icn breaking capacity at 230 V AC (50/60 Hz) means it can safely interrupt a fault current up to that level — enough for most residential and light commercial distribution boards.

Clip-on mounting to a standard DIN rail, occupying 2 x 9 mm pitches (18 mm total width). Torque to 2 N·m on the power circuit connections.

Frequently asked questions

What is the breaking capacity of A9D16806?

10,000 A Icn at 230 V AC, 50/60 Hz — sufficient for most final subcircuits in TN earthing systems.

What earth-leakage sensitivity does this RCBO have?

10 mA, which provides a high level of protection against electric shock, suitable for circuits supplying socket outlets in wet areas or where additional protection is required.

How do I get pricing and availability for A9D16806?

Submit an RFQ through this listing. The part is sourced to order through independent distribution; current pricing and stock position are confirmed at quote time.

MPN