Skip to main content
Schneider Electric A9D17840 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D17840 Acti9 IKQE RCBO, 40 A, 30 mA, Cu

MPNA9D17840
Obsolete

Schneider Electric Acti9 IKQE RCBO, 1P+N, 40 A rated current, 30 mA earth-leakage sensitivity, curve C, 10 kA breaking capacity at 230 V AC, DIN-rail clip-on, BS EN 61009-1.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9D17840 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9D17840 — Electrical Ratings
ParameterValue
Rated current (In)40 A at 50 °C
Rated operational voltage (Ue)230 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D17840 — Identification
ParameterValue
Product nameIKQE RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
A9D17840 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules2
Terminal connectionsTunnel type terminal (top or bottom) 1...16 mm² rigid without cable end Tunnel type terminal (top or bottom) 1...10 mm² flexible without cable end Tunnel type terminal (top or bottom) 1...10 mm² flexible with cable end
Wire stripping lengthPower circuit: 13 mm for top or bottom connection
Terminal tightening torquePower circuit: 2 N.m top or bottom
Width18 mm
Height118 mm
Depth82 mm
A9D17840 — Environmental
ParameterValue
Operating ambient temperature-15...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2
A9D17840 — Approvals
ParameterValue
StandardsBS EN 61009-1

Product details

The Schneider Electric A9D17840 is an Acti9 IKQE RCBO — a residual current breaker with overcurrent protection, combining earth-leakage and overcurrent trip in one 18 mm wide DIN-rail module.

The 10 kA breaking capacity at 230 V AC means it safely interrupts a fault up to that level; the limitation class 3 keeps let-through energy low enough to protect downstream wiring. The 30 mA earth-leakage sensitivity is the standard threshold for personal protection against indirect contact — catches a fault path through a person before fibrillation risk becomes significant.

Clip-on DIN-rail mount, 18 mm wide — that is two 9 mm pitches. Occupies one outgoing position in an Acti9 distribution board.

Frequently asked questions

What is the A9D17840 used for?

It is a combined RCBO for single-phase outgoing circuits in distribution boards, providing overcurrent protection (curve C) and 30 mA earth-leakage protection in one 18 mm DIN-rail module.

Where can I buy the A9D17840?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN