Specifications

A9D18845 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)100 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9D18845 — Electrical Ratings
ParameterValue
Rated current (In)45 A at 50 °C
Rated operational voltage (Ue)230 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D18845 — Identification
ParameterValue
Product nameIKQE RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
A9D18845 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules2
Terminal connectionsTunnel type terminal (top or bottom) 1...16 mm² rigid without cable end Tunnel type terminal (top or bottom) 1...10 mm² flexible without cable end Tunnel type terminal (top or bottom) 1...10 mm² flexible with cable end
Wire stripping lengthPower circuit: 13 mm for top or bottom connection
Terminal tightening torquePower circuit: 2 N.m top or bottom
Width18 mm
Height118 mm
Depth82 mm
A9D18845 — Environmental
ParameterValue
Operating ambient temperature-15...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2
A9D18845 — Approvals
ParameterValue
StandardsBS EN 61009-1

Product details

Rated 45 A at 50 °C on a C-curve, with 100 mA earth-leakage sensitivity and 10 kA Icn breaking capacity at 230 V AC.

At 82 mm deep and 118 mm tall, it clears most 100 mm-deep enclosures — but check gland-plate clearance if the busbar runs behind the RCBO. Neutral is on the left, which matters for pre-wired busbar alignment in Acti9 distribution boards.

Designed to BS EN 61009-1, the harmonised standard for RCBOs. Suitability for isolation confirmed, with an ON/OFF contact position indicator and provision for padlocking (Ø 4 mm padlock). IP20 finger protection — panel-mount only, not for wet environments.

Frequently asked questions

Where can I buy A9D18845 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

What is the breaking capacity of A9D18845?

10,000 A Icn at 230 V AC, 50/60 Hz — sufficient for most commercial and light industrial distribution subcircuits where the prospective fault current stays under that threshold.

What earth-leakage sensitivity does A9D18845 have?

100 mA, which suits distribution circuits where 30 mA devices would nuisance-trip on cable capacitance or equipment leakage.

MPN
A9D18845