Skip to main content
Schneider Electric A9D47216

Schneider Electric A9D47216

MPNA9D47216
Active

A9D47216 - IC60H RCBO 2P 16A 30MA B 10000A SI by SQUARE D

$147.32Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

A9D47216 key specifications
ParameterValue
Control typeToggle
Network typeAC
Product or component typeResidual current breaker with overcurrent protection (RCBO)
Voltage500 V AC 50 Hz
[Ue] rated operational voltage220...240 V AC 50 Hz
[Uimp] rated impulse withstand voltage4 kV
Surge current3000 A
Breaking capacity10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 15 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2
Current16 A
Residual current tripping technologyVoltage independent
[Ics] rated service breaking capacity7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 7.5 kA 50 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2
Network frequency50 Hz

All specifications

A9D47216 additional specifications
ParameterValue
Poles description2P
Number of protected poles2
IP degree of protectionIP40 (distribution enclosure) conforming to IEC 60529 IP20 conforming to IEC 60529
Mounting modeClip-on
Mounting supportDIN rail
Connection pitch9 mm between poles
Wire stripping length12 mm for top or bottom connection
Connections - terminalsTunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible Tunnel type terminal top or bottom 1...25 mm² flexible with ferrule
Relative humidity95 % at 55 °C
Depth78 mm
Width36 mm
ColorWhite
Height86 mm
Electrical durability10000 cycles
Mechanical durability20000 cycles
StandardsEN/IEC 60947-2 EN/IEC 61009-2-1
RangeActi9
Curve codeB
9 mm pitches4
Quality labelsNF IMQ KEMA-KEUR VDE
Tropicalisation2
Limitation class3 conforming to EN/IEC 61009-2-1
Local signallingON, OFF, fault trip
Device short nameiC60 RCBO
Tightening torque2 N.m
Device applicationDistribution
Overvoltage categoryIII conforming to IEC 60364
Trip unit technologyThermal-magnetic
Magnetic tripping limit3...5 x In
Earth-leakage protectionIntegrated
Device location in systemOutgoer
Earth-leakage sensitivity30 mA
Suitability for isolationNo conforming to IEC 60947-1
Contact position indicatorNo
Electromagnetic compatibility8/20 µs impulse withstand, 3000 A conforming to EN/IEC 61009-2-1
Earth-leakage protection classType A-SI (Super Immunised)
Rated breaking and making capacityIdm 6000 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Ambient air temperature for storage-40...70 °C
Earth-leakage protection time delayInstantaneous
Ambient air temperature for operation-25...60 °C
Comb busbar and distribution block compatibilityTop or bottom: YES Bottom: biconnect
MPN
A9D47216