Skip to main content
Schneider Electric A9D51625 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D51625 Acti9 iDPN Vigi RCBO, 25 A, 30 m

MPNA9D51625
Obsolete

Schneider Electric Acti9 iDPN Vigi, A9D51625, 1P+N RCBO, 25 A, 30 mA, B curve, 4500 A Icn, DIN rail, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9D51625 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON, OFF, fault trip
A9D51625 — Electrical Ratings
ParameterValue
Rated current (In)25 A
Rated operational voltage (Ue)220...240 V AC 50 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability10000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D51625 — Identification
ParameterValue
Product nameActi9 iDPN Vigi
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiDPNa Vigi
A9D51625 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsSingle terminal top or bottom 1...16 mm² rigid Single terminal top or bottom 1...10 mm² flexible Single terminal top or bottom 1...10 mm² flexible with ferrule
Wire stripping length15 mm for top or bottom connection
Terminal tightening torque2 N.m top or bottom
Width36 mm
Height85 mm
Depth73 mm
A9D51625 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Relative humidity95 % at 55 °C
Tropicalisation2 conforming to IEC 60068-1
A9D51625 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1

Product details

The Schneider Electric A9D51625 is an Acti9 iDPN Vigi combined overcurrent and earth-leakage circuit breaker (RCBO) in a 1P+N form factor, rated 25 A with 30 mA earth-leakage sensitivity and a B curve (magnetic tripping between 3 and 5 times In). The 30 mA sensitivity is the standard threshold for personal protection against indirect contact in final circuits per IEC 60364, making this unit suitable for socket-outlet circuits, lighting, and general-purpose distribution where both overcurrent and residual current protection are required in a single module. Breaking capacity is 4500 A Icn at 220…240 V AC, 50 Hz, conforming to EN/IEC 61009-2-1. The thermal-magnetic trip unit provides overload protection via the thermal bimetal and short-circuit protection via the solenoid.

This is a standard modular-device footprint that fits any DIN-rail enclosure without special adapters.

Frequently asked questions

What is the breaking capacity of the A9D51625?

The A9D51625 has a breaking capacity of 4500 A Icn at 220…240 V AC, 50 Hz, conforming to EN/IEC 61009-2-1.

Where can I buy the A9D51625?

The A9D51625 is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the earth-leakage sensitivity of the A9D51625?

The earth-leakage sensitivity is 30 mA, the standard threshold for personal protection in final circuits.

What standards does the A9D51625 comply with?

The A9D51625 complies with EN/IEC 61009-2-1 for combined overcurrent and residual current devices, and overvoltage category III per IEC 60364.

MPN