Schneider Electric Acti9 iDPN Vigi, RCBO, 1P+N, 6 A, B-curve, 30 mA earth leakage, 4500 A breaking capacity, DIN rail clip-on.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9D54606 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON, OFF, fault trip
A9D54606 — Electrical Ratings
ParameterValue
Rated current (In)6 A
Rated operational voltage (Ue)230...240 V AC 50 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability20000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D54606 — Identification
ParameterValue
Product nameActi9 iDPN Vigi
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiDPNa Vigi
A9D54606 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsSingle terminal top or bottom 1...16 mm² rigid Single terminal top or bottom 1...10 mm² flexible Single terminal top or bottom 1...10 mm² flexible with ferrule
Wire stripping length15 mm for top or bottom connection
Terminal tightening torque2 N.m top or bottom
Width36 mm
Height85 mm
Depth73 mm
A9D54606 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Relative humidity95 % at 55 °C
Tropicalisation2 conforming to IEC 60068-1
A9D54606 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1

Product details

The Schneider Electric A9D54606 is an Acti9 iDPN Vigi residual-current circuit breaker with overcurrent protection (RCBO) — one module wide, 1P+N, rated 6 A with a B tripping curve and integrated 30 mA earth-leakage protection. It combines a thermal-magnetic MCB and an RCD in a single DIN-rail unit, so a single device handles both overload/short-circuit and ground-fault protection on a final subcircuit. The 4500 A Icn breaking capacity at 230…240 V AC 50 Hz (per EN/IEC 61009-2-1) means it safely interrupts a fault up to 4.5 kA without welding or rupturing — adequate for most residential and light commercial distribution boards where the prospective short-circuit current stays under that threshold. The B-curve (magnetic trip at 3…5 × In) makes it a good fit for resistive or general-purpose loads with low inrush, like lighting circuits or socket outlets.

Clip-on mounting to DIN rail, 36 mm wide (4 × 9 mm pitches), 85 mm tall, 73 mm deep — standard modular footprint that slots into any Acti9 or Multi9 distribution board. Tightening torque 2 N·m, strip length 15 mm. IP20 on the front face, IP40 inside the modular enclosure — fine for dry indoor panels, not for washdown zones.

Frequently asked questions

What are the key ratings of the A9D54606?

Rated 6 A, B-curve (magnetic trip 3…5 × In), 30 mA earth-leakage sensitivity, 4500 A breaking capacity at 230…240 V AC 50 Hz, 1P+N, thermal-magnetic trip, pollution degree 3, overvoltage category III.

Where can I buy the A9D54606?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation does Schneider provide for the A9D54606?

The part is certified to EN/IEC 61009-2-1, tropicalised per IEC 60068-1 (class 2), and carries IP20/IP40 ratings per IEC 60529. Overvoltage category III per IEC 60364. Pollution degree 3.