Schneider Electric Acti9 iDPN Vigi, RCBO, 1P+N, 13 A, B-curve, 30 mA RCD, 4.5 kA breaking capacity, DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9D54613 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON, OFF, fault trip
A9D54613 — Electrical Ratings
ParameterValue
Rated current (In)13 A
Rated operational voltage (Ue)220...240 V AC 50 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability20000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D54613 — Identification
ParameterValue
Product nameActi9 iDPN Vigi
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiDPNa Vigi
A9D54613 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsSingle terminal top or bottom 1...16 mm² rigid Single terminal top or bottom 1...10 mm² flexible Single terminal top or bottom 1...10 mm² flexible with ferrule
Wire stripping length15 mm for top or bottom connection
Terminal tightening torque2 N.m top or bottom
Width36 mm
Height85 mm
Depth73 mm
A9D54613 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Relative humidity95 % at 55 °C
Tropicalisation2 conforming to IEC 60068-1
A9D54613 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1

Product details

The Schneider Electric A9D54613 is an Acti9 iDPN Vigi combined residual current circuit breaker with overcurrent protection (RCBO) — a single-module device that packs a 13 A thermal-magnetic MCB and a 30 mA earth-leakage trip into one 36 mm-wide DIN-rail housing. It is a 1P+N unit, meaning it switches the live conductor and monitors the neutral, with the neutral on the left side of the terminal layout. The B-curve characteristic (magnetic trip between 3 and 5 times In) makes it a natural fit for residential or light commercial final circuits where the inrush from connected loads is modest — think lighting, socket outlets, or general-purpose distribution.

The 4.5 kA Icn breaking capacity at 220–240 V AC conforms to EN/IEC 61009-2-1. That figure governs the maximum prospective fault current the device can safely interrupt. In a typical domestic or small commercial distribution board with a 6 kA or 10 kA upstream main breaker, this 4.5 kA rating means the RCBO is suitable for outgoing circuits where the fault level at the point of installation does not exceed that value — a coordination check the panel builder must confirm. The limitation class 3 rating (also per EN/IEC 61009-2-1) indicates good energy let-through performance, which helps with downstream selectivity. The integrated 30 mA residual current sensitivity covers the standard requirement for additional protection against direct contact in most IEC 60364 installations. The thermal-magnetic trip unit handles the overcurrent side — the thermal element protects against sustained overloads, the magnetic element against short-circuits. The device is rated for 20,000 electrical and 20,000 mechanical cycles, which is a solid endurance figure for a distribution RCBO. The 9 mm pitch between phase and neutral connections matches the Acti9 busbar system. The toggle provides local ON, OFF, and fault-trip indication.

Frequently asked questions

Where can I buy A9D54613?

The A9D54613 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of A9D54613?

The A9D54613 has a breaking capacity of 4500 A Icn at 220...240 V AC 50 Hz, conforming to EN/IEC 61009-2-1.

What is the residual current sensitivity of A9D54613?

The integrated earth-leakage protection is rated at 30 mA sensitivity.

What compliance documentation does this brand provide for A9D54613?

The A9D54613 is certified to EN/IEC 61009-2-1 and carries overvoltage category III per IEC 60364. It is tropicalised to class 2 per IEC 60068-1. Specific RoHS/REACH declarations are available from the manufacturer upon request.

MPN